Closed fixes summary
DCFM is allowing the user to create an Empty LAG.
No yellow dotted lines are shown when we configure EX-E within the
existing E-E connection.
VEX option got enabled in the Edit FCIP Tunnel dialog box, after editing
the circuit.
While editing a policy, if IP address is changed, it is not reflected in
the Trigger section in Event Policy main dialog box.
In Connection Properties table, E_Port of a 1606 extension SAN switch
is shown as gigE port.
Incorrect number of edits is shown in the error message when Compare
Merge dialog box is opened from the Activate Zone Config dialog
box.
Duplicate tunnels are shown in the FCIP Tunnel dialog box after creating
a new tunnel.
Unknown Badge is shown for all the Discovered B model switches in
DCFM professional edition.
DCFM Professional 10.3.0 gets unknown error message on launching
the Zoning dialog box. Users will be limited to use 300 KB maximum
for zone database size.
Alert message is not shown at the top of the Zoning dialog box when
user has made any zoning configuration through CLI.
When Changing the Look and feel option from Default to System, the
Connection properties of a Switch or End device is not properly dis-
played in the Topology.
When selecting the switch and adding to the zone the HBA virtual
ports are not getting added to the zone.
Client crashes on launch when the system is at JRE 1.6.0_14.
Internal error is given on modifying the SNMP credentials from Edit
Discovery dialog box.
Merge wizard says merge operation success, but the master log says
merge operation failed.
44
Solution
Workaround prior to upgrade: Check
for the dot1x status on the port before
assigning it to a LAG.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade:
Relaunching the client.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: Close
and reopen the Activate Zone Config
dialog box to complete the zoning
activation.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade: Close
and open the FCIP Tunnel dialog box
after sometime. We will not see the
duplicate tunnels.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Workaround prior to upgrade:
Manually select the virtual ports and
add to the zone.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.