6.
Type > slptool findsrvs service:wbem and press Enter to verify the SLP service is
advertising its WBEM services.
7.
Choose one of the following options to verify the SLP service is advertising the WBEM SLP template
over its configured client protocol adapters.
Type > slptool findattrs service:wbem:http://IP_Address:Port and press
Enter.
Type > slptool findattrs service:wbem:https://IP_Address:Port and press
Enter.
NOTE:
IP_Address:Port is the IP address and port number that display when you use the
slptool findsrvs service:wbem command.
DCFM Enterprise User Manual (Publication Number 53-1001775-01)
On page 46, in the Host discovery section, edit the "Configuring virtual machine credentials" procedure
as detailed above for the Professional User Manual.
On page 171, in the SMI Agent configuration section, add the Service Location Protocol (SLP) support
information as detailed above for the Professional Plus User Manual.
DCFM 10.4.0 fixes
Table 4
lists the fixes that were closed for this release.
Table 4 DCFM 10.4.0 closed fixes
Closed fixes summary
Blade instances are not returned for M-Model director type switches
Physical Package SubProfile: CP Blade Instances were not returned
while doing EnumerationInstance operation on Brocade_Blade class.
Enumeration, GetInstance and Executive query operations fail for
Brocade_Blade and Association/Reference operations fail for Bro-
cade_Blade class with resultant class as Brocade_Port Module. User
will not be able to traverse from Blade to Port module class when
Fabric OS-based director is used.
Instances are not returned for the class Brocade_SwitchFCPorRateStats.
User will not be able to traverse from SwitchFCPortRateStats to other
classes since no instance was returned.
Brocade_LogicalIdentity class is missing under Brocade_Fabric.MOF
but available in datamodel; CIM_ERR_NOT_FOUND exception is
given if any operations are performed on Brocade_LogicalIentity class.
User will get CIM_ERR_NOT_FOUND exception, since LogicalIdentity
class is not defined under Fabric MOF.
B-series Data Center Fabric Manager Enterprise, Professional Plus, and Professional
Solution
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.
Fixed in DCFM 10.4.0.