Brocade Communications Systems 8 Reference Manual page 33

Fabric os mib reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

3. Set the security level.
Fabric OS MIB Reference
53-1001768-01
swFabricWatchTrap: YES
DesiredSeverity:None
swTrackChangesTrap: YES
swIPv6ChangeTrap: YES
swPmgrEventTrap: YES
swFabricReconfigTrap: YES
swFabricSegmentTrap: YES
swExtTrap: YES
FA-TRAP: YES
connUnitStatusChange: YES
connUnitDeletedTrap: YES
connUnitEventTrap: YES
connUnitSensorStatusChange: YES
connUnitPortStatusChange: YES
FICON-TRAP: YES
linkRNIDDeviceRegistration: YES
linkRNIDDeviceDeRegistration: YES
linkLIRRListenerAdded: YES
linkLIRRListenerRemoved: YES
linkRLIRFailureIncident: YES
HA-TRAP: YES
fruStatusChanged: YES
cpStatusChanged: YES
fruHistoryTrap: YES
ISCSI-TRAP: YES
iscsiTgtLoginFailure: YES
iscsiIntrLoginFailure: YES
iscsiInstSessionFailure: YES
IF-TRAP: YES
linkDown: YES
linkUp: YES
BD-TRAP: YES
bdTrap: YES
bdClearTrap: YES
Example of systemGroup configuration (default)
switch:admin> snmpconfig --default systemGroup
*****
This command will reset the agent's system group configuration back to
factory default
*****
sysDescr = Fibre Channel Switch
sysLocation = End User Premise
sysContact = Field Support
authTraps = 0 (OFF)
*****
Are you sure? (yes, y, no, n): [no] y
switch:admin> snmpconfig --set secLevel
Select SNMP GET Security Level
(0 = No security, 1 = Authentication only, 2 = Authentication and Privacy, 3 =
No Access): (0..3) [0] 2
Select SNMP SET Security Level
(0 = No security, 1 = Authentication only, 2 = Authentication and Privacy, 3 =
No Access): (2..3) [2] 2
switch:admin> snmpconfig --show secLevel
GET security level = 2, SET level = 2
Loading Brocade MIBs
1
15

Advertisement

Table of Contents
loading

Table of Contents