The declaration 1 (unknown) maps to the default value upon rebooting, and 2 (invalid) is not
applicable.
Declarations 3 and 4 perform the same operation—a cold boot of the switch.
Values
Possible values are:
connUnitContact 1.3.6.1.3.94.1.6.1.23
Contact information for this connectivity unit.
Displays the same value as sysContact. Changing the value in this variable causes the value in
sysContact to also be changed.
connUnitLocation 1.3.6.1.3.94.1.6.1.24
Location information for this connectivity unit.
Displays the same value as sysLocation.
connUnitEventFilter 1.3.6.1.3.94.1.6.1.25
Defines the event severity logged by this connectivity unit. All events of severity less than or equal
to connUnitEventFilter are logged in connUnitEventTable.
Return
Always returns value 9 (debug).
connUnitNumEvents 1.3.6.1.3.94.1.6.1.26
Number of events currently in connUnitEventTable.
Values
For Fabric OS v3.0 this value ranges from 0 to 64.
For Fabric OS v4.0 this value ranges from 0 to 255.
For Fabric OS v4.2 this value ranges from 0 to 2048.
Fabric OS MIB Reference
53-1001768-01
onlineConnUnit = enable switch
default after reboot = unknown
unknown (1)
invalid (2)
resetConnUnitColdStart (3): Reboot. Performs a switch reboot.
resetConnUnitWarmStart (4): Fastboot. The addressed unit performs a Warm Start reset.
offlineConnUnit (5): Disable switch. The addressed unit puts itself into an
implementation-dependant offline state. In general, if a unit is in an offline state, it cannot be
used to perform meaningful Fibre Channel work.
onlineConnUnit (6): Enable switch. The addressed unit puts itself into an
implementation-dependant online state. In general, if a unit is in an online state, it is capable
of performing meaningful Fibre Channel work.
connUnitContact 1.3.6.1.3.94.1.6.1.23