3

fcFeError group

fcFeError group
This group consists of tables that contain information about the various types of errors detected.
The management station might use the information in this group to determine the quality of the
link between the Fx_Port and its attached Nx_Port.
Implementation of this group is optional.
fcFxPortErrorTable 1.3.6.1.3.42.2.1.3.1
This table contains one entry for each Fx_Port in the fabric element, and counters recording
numbers of errors detected since the management agent reinitialized.
The first six columnar objects after the port index correspond to the counters in the Link
ErrorStatus Block.
fcFxPortErrorEntry 1.3.6.1.3.42.2.1.3.1.1
An entry containing error counters of an Fx_Port.
Index
fcFxPortErrorModuleIndex, fcFxPortErrorFxPortIndex
fcFxPortErrorModuleIndex 1.3.6.1.3.42.2.1.3.1.1.1
Identifies the module containing the Fx_Port for which this entry contains information.
fcFxPortErrorFxPortIndex 1.3.6.1.3.42.2.1.3.1.1.2
Identifies the Fx_Port within the module. This number ranges from 1 to the value of
fcFeModulePortCapacity for the associated module. The value remains constant for the identified
Fx_Port until the module is reinitialized.
fcFxPortLinkFailures 1.3.6.1.3.42.2.1.3.1.1.3
The number of link failures detected by this Fx_Port.
fcFxPortSyncLosses 1.3.6.1.3.42.2.1.3.1.1.4
The number of loss of synchronization errors detected by the Fx_Port.
fcFxPortSigLosses 1.3.6.1.3.42.2.1.3.1.1.5
The number of loss of signal errors detected by the Fx_Port.