Brocade Communications Systems 8 Reference Manual page 174

Fabric os mib reference
Hide thumbs Also See for 8:
Table of Contents

Advertisement

5
swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2
swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2
(Obsoleted by swFabricWatchTrap)
Enterprise
sw
Variables
"swSensorStatus 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3"
"swSensorIndex 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1"
"swSensorType 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2"
"swSensorValue 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4"
"swSensorInfo 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5"
"swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10"
A swSensorScn (2) is generated whenever an environment sensor changes its operational state: for
instance, if a fan stop working. The VarBind in the Trap Data Unit contain the corresponding
instance of the sensor status, sensor index, sensor type, sensor value (reading), and sensor
information. Note that the sensor information contains the type of sensor and its number, in textual
format.
#TYPE
#SUMMARY
#ARGUMENTS
#SEVERITY
#TIMEINDEX
#STATE
swFCPortScn 1.3.6.1.4.1.1588.2.1.1.1.0.3
Enterprise
sw
Variables
"swFCPortOpStatus 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4"
"swFCPortIndex 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1"
"swFCPortName 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36"
"swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10"
"swFCPortFlag 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.38"
"swVfId 1.3.6.1.4.1.1588.2.1.1.1.2.15"
A swFCPortScn (3) is generated whenever an FC port changes its operational state: for instance,
the FC port goes from online to offline. The VarBind in the Trap Data Unit contain the corresponding
instance of the FC port's operational status, index, swFCPortName, and swSsn. swFCPortName
and swSsn are optional.
156
A sensor (temperature, fan, or other) changed its
operational state.
%s: is currently in state %d and SSN is #%s
4, 0, 5
Informational
1
Operational
Fabric OS MIB Reference
53-1001768-01

Advertisement

Table of Contents
loading

Table of Contents