5
swFwWriteActVals 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.14
swFwWriteActVals 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.14
This applies or cancels the alarm value changes.
For a read operation, the return value is always swFwCancelWrite.
The following are the custom alarm variables that can be modified:
Changes to these custom alarm variables can be saved by setting this variable to swFwApplyWrite.
Changes to these custom alarm variables can be removed by setting this variable to
swFwCancelWrite.
swFwDefaultChangedActs 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.15
Default action matrix for changed event.
swFwDefaultExceededActs 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.16
Default action matrix for an exceeded event. The exceeded value might be either above the high
threshold or below the low threshold.
swFwDefaultBelowActs 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.17
Default action matrix for below event.
swFwDefaultAboveActs 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.18
Default action matrix for above event.
swFwDefaultInBetweenActs 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.19
Default action matrix for in-between event.
swFwCustChangedActs 1.3.6.1.4.1.1588.2.1.1.1.10.2.1.20
Custom action matrix for changed event.