Specifying Alarm Output <Alarm Out - Sanyo VDC-DP9584N - Network Camera Instruction Manual

Color ccd camera
Table of Contents

Advertisement

Setting Alarm <ALARM>
4
Set <ALARM OUT> to "ON" or "OFF" for alarm
output.
·ALARM OUT
ON : Outputs alarm signal at alarm input detection.
• No alarm signal is output if the alarm input is received while the
monitor is displaying the settings screen.
OFF : No alarm signal output.
5
Select <MENU> – "BACK" and press the SET
button.
RReturns to the "ALARM SETTING" screen.
Note:
If an alarm is detected (including motion detection) during sequential
pan or auto pan, the sequential pan or auto pan stops for the time
set in <DURATION> (see page 40). The original operation is
resumed once the duration has elapsed.
37
ALARM IN SETTING
POLARITY
NO
MOVE
OFF
·ALARM OUT
OFF
Specifying Alarm Output <ALARM OUT>
1
Select <ALARAM OUT> and specify a polarity for
the signal.
·ALARM OUT
NO
: Normal Open (Closes when alarm input is detected.)
NC
: Normal Close (Opens when alarm input is detected.)
MEMO:
For the electrical characteristics of alarm output, the nominal
output of the open collector (grounded emitter) is 18 V 25 mA.
ALARM SETTING
ALARM IN
1
y
·ALARM OUT
NO
MOTION
OFF
uAREA
SET
y
uSENSITIVITY
SET
y
ZOOM
OFF
uZOOM TIME
5S
DURATION
5S
ALARM SIGN
OFF
PRESET
OFF
MENU
BACK