INSTALLATION MANUAL
Color CCD Camera
● For the customers in US and Canada
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO
ALL LOCAL CODES.
☞ Please read this manual before installing and using this camera, and always follow the instructions in it for
proper use.
Do not touch the lens and lens tube:
The lens and lens tube are composed of precision parts
that must be strictly kept untouched.
1
Remove the lens assembly.
1 Loosen the four screws (A) using the supplied hexagonal
wrench (large) (B) to remove the dome cover and the lens
cover.
2 Pull off the pin connector cables from CN401, CN403 and
CN406.
3 While holding the spring (C), pull the retainer (D) until it clicks.
CN406
Lens assembly
CN401
Lens cover
CN403
Lens/Lens tube
Dome cover
(A)
2
Install the camera unit base on the
ceiling or wall.
1 Make four screw holes and a cable hole in the supplied
cushioning sheet (E) using the supplied pattern sheet, and
then attach it to the back of the camera unit base.
• When routing the cables on the ceiling or the wall, open the
conduit hole cover (F) after removing a screw (G) using
supplied hexagonal wrench (small) (H) and pass the cables
through the conduit hole.
2 Make four screw hole marks (and a cable hole mark) on the
ceiling or the wall using the pattern sheet, and then drill the
screw holes (and cut a cable hole).
3 Pass the cables (I) through the cable hole and match the four
screw holes of both the camera unit base and the ceiling or
the wall. And then, secure it using the four or more screws (J)
through the washers.
(I)
(E)
(H)
(G)
(F)
(J)
(D)
Camera
Dome liner
window
(B)
(K)
Camera window
(J)
3
Replace the lens assembly on the
camera unit base.
1 Put the lens assembly back in its original position, then press
the retainer back into its original position.
2 Plug the pin connector cables to CN401, CN403 and CN406.
4
Make required
connections, and check
the image from the camera.
1 Refer to "CONNECTIONS" on the back.
2 Connect the MONITOR OUT pin and the
(C)
GND pin on the base circuit board to a
monitor using an alligator clip cable.
3 Holding in the manner shown on the right,
move the lens in the pan and tilt directions
and check the image on the monitor.
Note:
When the image is displayed upside down, fold
the lens assembly downward and turn it to the
left to avoid damage to the FFC cable.
5
Carry out the settings and
adjustment for the camera
using the on-screen menu.
Refer to the separate-volume instruction manual.
6
Secure the dome cover by tightening the
screws (A).
If a whole surface of the camera's lens does not show through
the camera window, loosen the screw (K) and adjust the dome
liner.
Note:
• When monitoring lighting or other extremely bright objects (which
exceed the maximum required illumination), smearing may occur in
the vertical or horizontal direction (either above and below the
high-brightness object or as a perpendicular band). In such a case,
adjust the angle of illumination and other factors while observing the
monitor.
• When installing the camera, make sure to properly perform
waterproofing for the holes in the ceiling or the wall.
• When setting up this camera, make sure that it is installed securely.
Check that the installation location is strong enough to bear the
camera weight before proceeding. Install to the ceiling or a wall that
has no surface unevenness. And be sure to embed the screw into the
ceiling or wall to a depth of at least 35 mm and a diameter of at least
3.5 - 5 mm. If the screw holes are too shallow, the camera may fall
down. In addition, do not touch the camera unit except when settings
and adjustments are necessary.
• Install where the temperature range will stay between –10°C (14°F)
and 50°C (122°F). (No condensation)
• The camera unit can be installed with the dome cover pointing
upward.
• If operated in an environment where the temperature may fall below
–10°C (14°F), attach the heater option board (VA-50H) to this camera
unit.
VDC-DP7584
VDC-DP7585P
GND
MONITOR
OUT

Advertisement

loading

Summary of Contents for Sanyo VDC-DP7585P

  • Page 1 INSTALLATION MANUAL Color CCD Camera ● For the customers in US and Canada THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL CODES. ☞ Please read this manual before installing and using this camera, and always follow the instructions in it for proper use.
  • Page 2 CONNECTIONS Basic Connection for Monitoring and Power Supply DC 12 V connection AC 24 V connection Check that polarity is correct. ~ ~ GND 18 AWG or more White Black BNC type Cable type RG-59U (3C-2V) RG-6U (5C-2V) RG-11U (7C-2V) •...

This manual is also suitable for:

Vdc-dp7584