Configuring the Communication Settings
5
Set [TERMINATE] to "ON" or "OFF".
CONTROL SETTING
BAUD RATE
19200
·
TERMINATE
ON
ON : Camera is the cabling termination.
OFF : No termination
6
Set [MENU] to "BACK" and press the SET button.
RReturns to the OPTION screen.
Setting Camera Address <ADDRESS>
7
Select [ADDRESS] and specify an address for the
camera (0 - 127).
OPTION
TITLE
OFF
PRIVACY MASK
SET
PASSWORD
SET
ALARM
SET
LANGUAGE
SET
CONTROL
COAX
·
ADDRESS
1
ALARM LINE OUT
OFF
29
GB
y
y
y
y
y
Setting Alarm Output to Communication
Line <ALARM LINE OUT>
8
Set [ALARM LINE OUT] to "ON" or "OFF".
OPTION
TITLE
OFF
PRIVACY MASK
SET
PASSWORD
SET
ALARM
SET
LANGUAGE
SET
CONTROL
COAX
ADDRESS
1
·
ALARM LINE OUT
OFF
PRESET
OFF
MENU
BACK
ON : Outputs alarm signals to communication line.
OFF : No output