Setting Alarm <ALARM>
If you have connected an external door switch or an infrared sensor, specify the following settings. This unit has a built-in
motion sensor, which outputs alarm signals when any moving subject, such as a would-be intruder, is detected.
1
Select [OPTION] and press the SET button.
RThe OPTION screen appears.
2
Select [ALARM] and press the SET button.
OPTION
TITLE
OFF
PRIVACY MASK
SET
PASSWORD
SET
·
ALARM
SET
LANGUAGE
SET
CONTROL
COAX
ADDRESS
1
ALARM LINE OUT
OFF
PRESET
OFF
MENU
BACK
23
GB
y
y
RThe ALARM SETTING
y
screen appears.
y
y
Specifying Alarm Input <ALARM IN>
3
Select [ALARM IN] and specify a polarity for the
signal.
ALARM SETTING
·
ALARM IN
NO
MOTION
OFF
u
AREA
SET
u
SENSITIVITY
SET
ZOOM
OFF
u
ZOOM TIME
5S
DURATION
5S
ALARM SIGN
OFF
PRESET
OFF
MENU
BACK
NO : Normal Open (When closed, detects an alarm input.)
NC : Normal Close (When opened, detects an alarm input.)
■ About an alarm sign
• You can use the alarm setting so that the displayed image will be
zoomed in when the signal is input (see page 26).
• Alarm sign indicates when an alarm signal is input (see page 27).