Alarm Settings (ALARM)
8
Use the joystick lever (xy) to select [DURATION]
and use the lever (vw) to select the interval after
which the next alarm becomes in effect.
When an alarm is detected, another alarm signal will not be
output until the duration specified in this setting has passed.
Available settings: 5S, 10S, 15S, 20S, 30S, 45S, 1M, 2M,
3M, 4M, 5M (S: Second, M: Minute)
Memo: The interval setting for the next alarm to become in effect is
applied to the external switch whose number is the same as
the alarm input number. The alarm input from other external
switches will be accepted.
• When the alarm input is used as the external control
input of the Day/Night function, "D/N" appears in the
top right of the screen. In this case, settings other
than [POLARITY] cannot be made.
• When multiple alarm inputs are received
simultaneously, the input whose alarm number is
smaller precedes the others.
After completing setting, use the lever to move the cursor to
[MENU] and select "BACK" or "END".

B Setting the alarm output (ALARM OUT)

The ALARM OUT screen allows you to perform the alarm output
settings for each alarm output number.
ALARM
ALARM IN
ALARM OUT
ALARM DISABLE
MOTION
ALARM DISPLAY
PRESET
MENU
1
Use the joystick lever (xy) to select [ALARM OUT],
use the lever (vw) to select an alarm output number
(1- 2), and press the [ENTER] button.
The ALARM OUT screen appears.
ALARM OUT 1
OUTPUT
POLARITY
ALARM TIME
PRESET
MENU
1
y
1
y
OFF
OFF
OFF
OFF
BACK
ON
NO
5S
OFF
BACK
2
Use the joystick lever (xy) to select [OUTPUT] and
use the lever (vw) to select an alarm output option.
Available settings:
• OFF:
Does not output the alarm signal.
• ON:
Outputs the alarm signal.
• REMOTE: Outputs the alarm signal by remote operation.
(This option is available only when [ALARM
OUT] is set to "2".)
• When selecting "REMOTE", "MANU" is
available for [ALARM TIME] enabling the
manual operation of the alarm output.
• When selecting "REMOTE", the alarm signal
will not be output automatically even when the
alarm is detected.
3
Use the joystick lever (xy) to select [POLARITY]
and use the lever (vw) to select the polarity for the
alarm output signal.
Available settings:
• NO (Normal Open):
Normally open so closed condition is detected as output.
• NC (Normal Close):
Normally closed so open condition is detected as output.
4
Use the joystick lever (xy) to select [ALARM TIME]
and use the lever (vw) to select a duration for which
the alarm signal is output.
The connected devices such as recorder, alarm buzzer and
warning lamp will operate for the duration you have specified.
Available settings: 2S, 5S, 10S, 15S, 20S, 30S, 45S, 1M,
2M, 3M, 4M, 5M, MANU
(S: Second, M: Minute)
Memo: "MANU" appears only when "REMOTE" is selected for
[OUTPUT] in step 2.
After completing setting, use the lever to move the cursor to
[MENU] and select "BACK" or "END".
The alarm output duration for remote operation
The alarm output duration when using remote operation depends on
the setting for [ALARM TIME].
• When selecting the value between "2S" and "5M":
Outputs the alarm for the duration you have specified.
• When selecting "MANU":
Controls the alarm output duration by the AUX6 operation
(ON/OFF) from external device.
While the alarm is output using remote operation, normal
alarm output cannot be used.
40