Mounting The Switch On A Workbench - H3C LS-5500-28C-PWR-SI-OVS Installation Manual

S5500-si complete series
Table of Contents

Advertisement

Installation Manual
H3C S5500-SI Complete Series Ethernet Switches
Figure 3-13 Effect diagram of front mounting ear and guide rail installation
Note:
Ensure a clearance of 1U (44.45 mm, namely, 1.75 inches) between devices for the
purpose of heat dissipation.

3.1.2 Mounting the Switch on a Workbench

In many cases, standard 19-inch racks are not available. Therefore, switches are often
placed on clean workbenches. To place your switch on a workbench, you simply need
to:
Make sure that the workbench is clean, flat, and sturdy.
Makes sure that the environment is well ventilated and allow 10 cm (3.9 in.) of
space around the chassis for heat dissipation.
Do not place heavy objects on your switch.
In the case of stack application, the vertical distance between two switches must
be at least 1.5 cm (0.59 in).
Rear panel
3-10
Chapter 3 Installing the Switch
Guide
rail

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents