For jobsites with extra-challenging interference, consider a scan-pick-pair of
the first band at the noisiest point (such as next to the power transformer),
then scan-pick-pair the second band at the second-noisiest point (such as
over railroad tracks). This gives you a specifically tailored band for each of the
two most difficult locations along your drill path.
To use different scans for the Up and Down bands, you must
pair the first band before scanning for a second band.
STEP 2 OF 10
Ensure all transmitters are powered off or more than 100 ft (30.5 m) away
from the locator.
STEP 3 OF 10
From the Main menu, select
Frequency optimization.
STEP 4 OF 10
Click the blue arrow to start
the scan.
STEP 5 OF 10
When the noise bars appear, walk the
intended drill path to find the two
locations with the highest levels of
noise, then return
DIGITAL CONTROL, INC
DIGITRAK FALCON F5+
DCI DigiGuide
USER MANUAL
11.04.2023
68
Need help?