Configuring the Guardian Service Processor (GSP)
Step 2. At the GSP prompt, enter the Security options and access control (SO) command:
GSP> so
Step 3. The first prompt you will see with the so command is for the following GSP-wide parameters:
Login Timeout: 1 minutes.
Number of password Faults allowed: 3.
Flow Control Timeout: 5 minutes.
The terminal will then display:
Do you want to modify the GSP wide parameters? (Y / [N]) __
Enter
to modify GSP-wide parameters, or enter
Y
If you enter Y, the parameters will be displayed in an edit mode to allow modification.
If you enter N, continue to the next step.
NOTE
Step 4. The terminal will display:
Do you want to modify the user number 1 parameters? (Y/[N]/Q to quit) __
Enter
to modify user number 1 parameters, enter
Y
unchanged or enter
If you enter Y, the parameters will be displayed in an edit mode to allow modification.
If you enter N, the terminal will display:
Do you want to modify the user number 2 parameters? (Y/[N]/Q to quit) __
Enter Y, N, or Q and proceed according to the instructions shown above in this step.
Be sure to read each prompt carefully and enter the correct response. A missed or incorrect
CAUTION
entry could deny entry to that user.
The following list is an example of added users information:
User's Name: Joe Smith
Organization's Name: IT Support
Dial-back configuration: Disabled
Access Level: Operator
Mode: multiple
User's state: enabled
For the number 1 user, the Access level is administrator.
A Mode entry of single only allows entry for that user one time, after which, further logon attempts are denied
and the user state is set to disabled.
A Mode entry of multiple allows unlimited logon access to the GSP for that user.
114
The first user entered (user number 1) is identified as the GSP administrator.
If you are adding users, you will need to step through all current user entries to
reach the next available user prompt.
to quit and return to the GSP prompt.
Q
to continue to add users.
N
to leave user number 1 parameters
N
Chapter