1
Figure 4-39. Finger Holes on back side of 4U library I/O Station
Populating the Library with Data Cartridges
For information on working with the cartridge magazines, see "Cartridge
Magazines" on page 4-30.
1. Unlock the cartridge magazines.
2. Remove all magazines from the library.
3. Insert cartridges in the left magazine(s). Do not store cartridges in the I/O
4. Insert cartridges in the right magazine(s).
5. Put all magazines back into the library. The library will automatically start up
v Using the Operator Control Panel: Control → Magazines
v Using the Web User Interface: Manage Library → Release Magazine
Note: The magazines will relock after 15 seconds if they have not been
removed.
Station or in the dedicated cleaning cartridge slot. See "2U Library I/O Slot,
Storage Slots and Drive Slot Element Addresses and Physical Locations" on
page A-1 or "4U Library I/O Slots, Storage Slots, and Drive Slots Element
Addresses and Physical Locations" on page A-2 for determining slot location.
and perform an inventory check.
Chapter 4. Installation and Configuration