2U Library
Figure 10-8. Diagrams for applying conductive tape for ESD protection to the back of a drive sled installed in a 2U or
4U library
13. Push the black tab ( 8 in Figure 10-5 on page 10-4) back underneath the
14. Upgrade library firmware and drive firmware to the latest version.
15. Run the Library Verify test. (Operator Control Panel: Service → Library
16. Return the failed drive sled to Dell.
Replacing a Power Supply
Note: The small gray markers show where conductive tape should be placed
to provide ESD protection.
library. When inserted properly, only the handle of the tab will be visible.
Note: Go to http://support.dell.com to download the latest firmware for your
library and tape drive(s).
Verify). This test requires the use of a scratch (blank) cartridge.
v If the test passes:
– When prompted by the Operator Control Panel display and the I/O
Station opens, remove the cartridge used in the test.
– Close the I/O Station by pushing it back into the library.
– Press Cancel to exit the Library Verify screen.
– Resume normal library operations.
If the test fails, an error code will be displayed. Make note of the error,
v
then refer to the Troubleshooting chapter in this document for additional
instructions.
1. Power OFF the library by pressing and holding down the power button for 4
seconds.
2. Disconnect the power cord from the electrical source, then from the library.
4U Library
Chapter 10. Check, Adjust, Remove, and Replace