v The Clean LED will only be lit when a cleaning REQUIRED has been issued by
v The Attention LED will indicate one of the following conditions.
Problem
Bad media
Drive sled issues
Redundant power supply failed
Power supply fan failure
v The Error LED will be lit when there is an unrecoverable (i.e. hard) drive or

Input Modes

There are several ways to enter values in the different menu items. These values
are selectable predefined values, toggle values (for example, ON/OFF) and
numerical values like network addresses.
Selecting Predefined Values
1. To set the predefined values, press the SELECT button to select the menu item.
2. Using the UP and DOWN buttons, select one of the various predefined values
3. As soon as the Operator Control Panel display shows the correct value, press
the drive. The LED will be turned OFF after a successful drive cleaning
operation.
library failure. This will happen at the same time the hard error message is
displayed on the screen and the LED will remain lit until the error state is
resolved.
Note: From the Operator Control Panel, run Service → Library Verify. If Library
Verify runs without error, the Error LED will be turned off. If the error
persists, recycle power.
for that item.
the SELECT button to apply the value.
Action Required
1. Go to Monitor → Inventory to locate the defective
cartridge.
2. Move the defective cartridge to the I/O Station.
(Operator Control Panel: Control → Move Cartridges).
3. Open the I/O Station to remove the defective
cartridge. (Operator Control Panel: Control → Open
I/O).
Do one of the following:
- Install a drive sled (see "Replacing a Tape Drive Sled"
on page 10-3).
- Modify or resubmit Logical Library setting (Operator
Control Panel: Configure → Logical Libraries or Web
User Interface: Configure Library → Logical Libraries).
- Restore defaults (Operator Control Panel: Configure →
Restore Defaults or Web User Interface: Configure
Library → Restore Defaults). -
Complete the following steps:
1. Replace the failed power supply (see "Replacing a
Power Supply" on page 10-7).
2. Cycle library power.
Replace the power supply.
Chapter 2. User Interfaces
2-3