32
Cast Bypass Top Plate Removal /
Installation
1. Allow the stove to burn out and cool down, until cool to touch.
2. Open stove door to access secondary air tube.
3. Remove secondary air tube–(see previous page).
4. 8 bolts secure the cast bypass top plate to the roof of the stove.
Before removing the bolts securing the cast bypass - support the cast up
with 2 X 12-1/4" 2 x 4 's. The cast bypass opening weighs 30lbs - DO NOT
REMOVE the bolts on the cast bypass prior to supporting the weight to
avoid damage and injury.
Cast bypass opening
View of inside top of stove
5. Remove the cast bypass opening top plate and replace.
6. Reverse steps to reinstall.
32 |
Regency i3000A/i3000R

Fan Operation Into Auto Mode

If fan will not come on in auto mode see the following possible causes and
solutions:
Possible causes:
- Bypass damper is open
- Brand new unit or first burn of the season
- No ember bed established (embers or coals, not to be mistaken with ashes)
- Primary damper is set to low (all the way to the left)
- There are only a couple small logs on fire or fire is almost out
- Mechanical issues or defects
Solutions:
- Close bypass once unit is at optimum temperature
- Establish a two inch ember bed
- Set damper between medium to high (middle or all the way to the right)
- Add a few more logs onto the fire
- See your authorized dealer
NOTE: The temperature displayed on the catalyst monitor
has nothing to do with the activation temperature in
auto for the fan.
The automatic sensor for this appliance is located at
the firebox base. If the temperature at this location is
not met, the fan will not come on. It is crucial on this
appliance to get this up to operating temperature so
that the catalyst is activated and bypass may be closed
to retain heat within the firebox.