Regency PG36NG5-R Owners & Installation Manual

Gas log fireplace
Hide thumbs Also See for PG36NG5-R:

Advertisement

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certified by the Australian Gas
Association for installation and operation
as described in these Installation and
Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
PG36 Gas Log Fireplace
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
an authorised installer, service agency or the
gas supplier.
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or
any other appliance.
Installation and service must be performed by
an authorised installer, service agency or the
gas supplier.
918-744d
Models: PG36NG5-R
PG36LPG5-R
FOR YOUR SAFETY:
What to do if you smell gas:
Do not try to light any
appliance
Do not touch any electrical
switch: do not use any phone
in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas
supplier's instructions.
If you
cannot reach your
gas supplier, call the fire
department.
04/08/15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PG36NG5-R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Regency PG36NG5-R

  • Page 1 Owners & Installation PG36 Gas Log Fireplace Models: PG36NG5-R PG36LPG5-R PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY: Improper installation, adjustment, alteration, What to do if you smell gas: service or maintenance can cause injury or Do not try to light any property damage.
  • Page 2: To The New Owner

    As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace.
  • Page 3: Table Of Contents

    Flush Front Accessories ..........43 Log Set Installation ............22 Premium Flush Front Assembly........44 Standard Flush Door ...........24 Cast Faceplate Assembly ..........45 Premium Flush Front Installation .........25 Wiring ................29 WARRANTY Remote Control ............31 Operating Instructions ..........31 Warranty ..............46 Regency PG36-5 Gas Log Fireplace ®...
  • Page 4: Data Badge

    DATA BADGE DATA BADGE NOTE: Regency This is a copy of the label that accompanies The label is located on the front inside base of the units are ® constantly being improved. Check the label on each PG36 Zero Clearance Room Sealed Gas unit, visible when the bottom louvre is open.
  • Page 5: Installation

    ON OR NEAR THE APPLIANCE. DO NOT USE AEROSOLS IN THE VICINITY OF 15) The appliance area must be kept clear and THIS APPLIANCE. free of combustible materials, (gases and other flammable vapours and liquids). Regency PG36-5 Gas Log Fireplace ®...
  • Page 6: Clearances

    Flat on Wall Corner with these instructions. are not adhered to. Recessed into Wall/Alcove Corner Clearance to Combustibles from: Back 0" (0mm) Side 0" (0mm) Floor " (0mm) Regency PG36-5 Gas Log Fireplace ®...
  • Page 7: Combustible Mantels

    INSTALLATION Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board. Regency PG36-5 Gas Log Fireplace ®...
  • Page 8: Mantel Leg Clearances

    4) The top of the unit must not be closer than 32" (813mm) to the ceiling. Maintain a physical gap between lining and spacers 2-5mm. (5mm clearance to framing each side). Regency PG36-5 Gas Log Fireplace ®...
  • Page 9: Unit Assembly Prior To Installation

    * For "C" screw position the top facing Each Co Axial Flue gas appliance must use support is reversed. it's own separate flue system. Common flue systems are prohibited. Regency PG36-5 Gas Log Fireplace ®...
  • Page 10: Exterior Flue Termination Locations

    (IV) A flue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free flow of air at the appliance is achieved. Regency PG36-5 Gas Log Fireplace...
  • Page 11: Flueing

    2) Only Flex pipe purchased from Regency may be used for Flex installations. ® 3) If you are installing the PG36 into a Regency Mantel Kit, use the minimum horizontal vent height (centre-line of 1029mm). Remember ® to include the mantel base in your calculations and to maintain the 32mm clearance (38mm with Flex) to the underside of the mantel top.
  • Page 12: Simpson Dura-Vent Flueing

    Vinyl Siding Shield for Riser Flue 903B 36" (914mm) Pipe Length - Black Snorkel - 14"(356mm) Rise Term.Cap Terminal 48" (1219mm) Pipe Length - Galv. Snorkel - 36" (914mm) Rise 902B 48" (1219mm) Pipe Length - Black Termination Cap Regency PG36-5 Gas Log Fireplace ®...
  • Page 13: Flueing Arrangements - Horizontal Terminations

    4" (102mm) inner diameter 6-7/8" (175mm) outer diameter A flue guard should be used whenever the termination is lower than the specified minimum or as per local codes. Note: Regency Co Axial Flue System ® (Flex) is only approved for horizontal terminations. 1029mm...
  • Page 14: Flueing Arrangements - Horizontal Terminations

    INSTALLATION FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS SIMPSON DURA-VENT DIRECT FLUE GS SYSTEM and REGENCY CO AXIAL FLUE SYSTEM (FLEX) ® (LPG & NG) The diagram below shows examples of horizontal termination arrangements using two 90 elbows (two 45 elbows equal one 90 elbow).
  • Page 15: Flueing Arrangements - Vertical Terminations

    Fireplace," "Combustible Mantels," "Mantel Leg Clearances" & "Framing and Finishing" sections. Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994). Note: Regency Co Axial Flue System (Flex) is only approved for horizontal terminations. ® Diagram 1...
  • Page 16 Firestops are required at each floor level and whenever passing through a wall. • Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas Fireplace," "Combustible Mantels," "Mantel Leg Clearances" & "Framing and Finishing" sections. Diagram 3 Regency PG36-5 Gas Log Fireplace ®...
  • Page 17: Horizontal Terminations

    Note: Apply sealant "Mill-Pac" to inner Wall Thimble (Part # 620-926) over the flue pipe and high temperature silicone Diagram 5 pipe. sealant to outer pipe on every twist- lock joint. Regency PG36-5 Gas Log Fireplace ®...
  • Page 18: Vertical Terminations

    3.25 0.99 over 11/12 to 12/12 1.22 over 12/12 to 14/12 1.52 over 14/12 to 16/12 1.83 over 16/12 to 18/12 2.13 over 18/12 to 20/12 2.29 over 20/12 to 21/12 2.44 Diagram 3 Regency PG36-5 Gas Log Fireplace ®...
  • Page 19: Gas Connection

    11) Main Gas Inlet Flue System: Simpson Dura-Vent Direct manual shut-off valve during any pressure Vent System or Regency Direct ® testing of the gas supply piping system at test Vent System (Flex) pressures equal to or less than 1/2 psig.
  • Page 20: Conversion From Ng To Lpg

    14) Carefully pull out the control box from underneath the fi rebox. Note: The control box is held in place with velcro. Burner Orifi ce Pull out the pilot hood by hand. Pilot Hood Regency PG36-5 Gas Log Fireplace ® 918-577 12/20/06...
  • Page 21 Jumper Location After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifi ce of the pressure. Put back the modulator plastic cap. Jumper Regency PG36-5 Gas Log Fireplace ® 918-577 12/20/06...
  • Page 22: Optional Brick Panels

    2nd grate tab. 02-53 02-49 Vermiculite Vermiculite Vermiculite 3) Place the Log 02-49 on the rear log support 02-51 pins with the flat side to the back. Cutouts 2nd Grate Tab Regency PG36-5 Gas Log Fireplace ®...
  • Page 23 02-49 02-50 02-52 02-53 02-51 02-54 Front Brackets Log indentation 02-55 02-52 02-50 02-53 Rear Grate 02-54 Photo shows rear grate tab. Notch Log 02-51 was removed to show the positioning of Log 02-52. Regency PG36-5 Gas Log Fireplace ®...
  • Page 24: Standard Flush Door

    Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely Note: Top and bottom louvres are on the unit. Diagram 2. different. Diagram 2 Regency PG36-5 Gas Log Fireplace ®...
  • Page 25: Premium Flush Front Installation

    9) Lift the module off of the velcro from the base of the fi rebox and pull out slightly. 10) Disconnect the wire harness on the module that is connected to the valve. Manual Control Switch Bracket Regency PG36-5 Gas Log Fireplace ® 08/16/07 918-637a...
  • Page 26 14) Place the wire grommet back into the thermodisc cover with the 2 female ends of the wires inside the cover as shown. 19) Remove the left side bottom hinge bracket by undoing the 2 screws. Regency PG36-5 Gas Log Fireplace ® 918-637a...
  • Page 27 28) Align the bottom louver mounting tab with hinges on the left and right side and secure using 2 screws on each side. 22) Connect new wire harness to the module and to the valve. Module Valve Regency PG36-5 Gas Log Fireplace ® 918-637a 08/16/07...
  • Page 28 NOTE - PG36 UNITS ONLY: For the wire cover to fi t in place on the PG36 the top half of the wire cover will need to be broken off by bending back and forth. Bend Here Regency PG36-5 Gas Log Fireplace ® 918-637a...
  • Page 29: Wiring

    This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Regency PG36-5 Gas Log Fireplace ®...
  • Page 30 INSTALLATION WIRING WITH PREMIUM FLUSH FRONT OPTION Regency PG36-5 Gas Log Fireplace ®...
  • Page 31: Remote Control

    OPERATING INSTRUCTIONS REMOTE CONTROL FIRST FIRE LIGHTING INSTRUCTIONS Use the Regency Remote Control Kit approved ® The FIRST FIRE in your heater is part of the for this unit. Use of other systems may void paint curing process. To ensure that the paint 1) Plug the power cord into a power outlet.
  • Page 32: Operating Instructions

    Listed below are some examples. All are normal operating sounds and should not be considered NOTE: If you have an incorrect flame pattern, as defects in your appliance. SUMMARY OF contact your Regency dealer for further ® instructions. Blower: CONTROLS...
  • Page 33: Copy Of The Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION. Regency PG36-5 Gas Log Fireplace ®...
  • Page 34: Maintenance

    NOT BE PLACED ON OR NEAR heat resistant paint (not with wall paint). being exposed to cold weather. THE APPLIANCE. Regency uses StoveBright Paint - Metallic ® Black #6309. 4) Inspect joints, to verify that no pipe...
  • Page 35: Gold Or Brass Louvres & Trim

    5/8" flat glass gasket for the Bay Front (Part # 936-243) and a tadpole glass gasket for the Flush Front (Part # 936-155). DOOR GLASS Your Regency fireplace is supplied with high ® temperature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce.
  • Page 36: Removing Valve Tray

    13) To replace the burner tray assembly reverse these instructions. 8) Remove the 10 Philips screws which secure the valve tray 14) Check for any gas leaks. assembly. 15) Check for proper flame appearance and glow on logs. Regency PG36-5 Gas Log Fireplace ®...
  • Page 37: Fan Replacement

    5) Unplug the 6 pin Molex connector and carefully pull out the ECS box. ECS Box 6 Pin Molex Connector 6) Remove the electric cover by undoing the 2 screws, pull out the grommet and the harness. Electric Cover Regency PG36-5 Gas Log Fireplace ®...
  • Page 38: Manual Control Switch Replacement

    12) Re-install the heat shield on the ECS box. 6) Pull out the ECS box by carefully lifting it up off the velcro. 13) Put the ECS box back in place under the firebox. 14) Reverse steps 5 to 1. ECS Box Regency PG36-5 Gas Log Fireplace ®...
  • Page 39: Parts List

         *Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509 The Control Box Cable wires for the IG35 come separately: 910-530, 910-504, 910-528 Regency PG36-5 Gas Log Fireplace ®...
  • Page 40: Main Assembly

    35) * Brick Panel - Right 511-031 Brick Clip (each) 918-744 Manual 513-968 Conversion Kit - NG to LPG *Not available as a replacement part. BRICK PANEL SET DOORS & LOUVERS PLEASE REFER SEPARATE SECTION Regency PG36-5 Gas Log Fireplace ®...
  • Page 41: Burner Assembly & Log Set

    Middle Right Log 94) * Front Left Log 95) * Center Left Log 96) * Center Right Log 97) * Front Bottom Log 98) * Middle Left Log *Not available as a replacement part. Regency PG36-5 Gas Log Fireplace ®...
  • Page 42: Bay Front Assembly

    120) * Flush Glass Retainer Bracket 112) * Bay Front Trim -Top/Bottom 780-934 Bay Door Trim - Gold *Not available as a replacement part. 113) * Bay Door Trim-Gold-Bottom 114) * Bay Door Trim-Gold-Top Regency PG36-5 Gas Log Fireplace ®...
  • Page 43: Flush Front Accessories

    Finishing Trim (4 piece) - Steel 157) * Finishing Trim Left 158) * Finishing Trim Top 159) * Finishing Trim Right 160) * Finishing Trim Bottom 161) 513-949 Flush Door Screen Pkg. *Not available as a replacement part. Regency PG36-5 Gas Log Fireplace ®...
  • Page 44: Premium Flush Front Assembly

    Part # Description 516-916 Premium Flush Front - Black 516-948 Wiring 910-975 Thermodisc 180) * Top Louver 181) * Bottom Louver 182) * Thermodisc Mounting Bracket 183) * Spacers *Not available as a replacement part. Regency PG36-5 Gas Log Fireplace ®...
  • Page 45: Cast Faceplate Assembly

    202) * Cast Faceplate - Top 203) * Cast Faceplate - Left 513-996 Cast Grills (Set) - Black Enamel (Aust. only: 240 volt) 204) * Cast Grill - Top 205) * Cast Grill - Bottom Regency PG36-5 Gas Log Fireplace ®...
  • Page 46: Warranty

    Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
  • Page 47 NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Regency PG36-5 Gas Log Fireplace ®...
  • Page 48 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Pg36lpg5-r

Table of Contents