Note!
For positioning, please also observe the information in chapter 3 "Location and safety instructions".
Tabel-top unit
Position the drip tray in the space provided below the water outlet.
Stand-alone unit
In the stand-alone version, the drip tray must be connected to the water tank. Remove the plug of the drip
tray and connect the level sensor.
5.5
CO
GAS CYLINDER: CALCULATION, INSTALLATION & CHANGE
2
Note!
Only use food grade CO
Caution!
Observe the manufacturer's warnings and transportation and storage regulations.
Protect gas cylinders from excessive heat, mechanical damage and corrosive substances.
Do not connect or store gas cylinders in zones with an increased fire hazard.
Place gas cylinders at a distance of at least 0.5 m from radiators.
Place gas cylinders so that they are easily accessible.
Place gas cylinders away from emergency exits and escape routes.
Store full and empty gas cylinders separately and according to the type of gas.
Gas cylinders may only be stored and transported when the covering cap is screwed on.
Gas cylinders must be stored upright and secured against falling over.
Only connect gas cylinders with pressure reducers and safety valves.
In the event of leaks or fire: close the cylinder valves immediately. Cool heated cylinders with water.
In workshops and laboratories, set up only as many reserve cylinders as you need for continuous operation.
Do not oil or grease cylinder valves.
Close the cylinder valves when the unit is to be decommissioned or when the gas cylinders are empty.
EN
Danger from CO
For safety reasons, the CO
is recommended to determine the maximum CO
installation according to the available room size or the available room volume.
38
(E290).
2
gas!
2
concentration in the room should not exceed 3% in the event of gas leakage. It
2
cylinder content in advance of the CO
2
gas cylinder