Download Print this page

BWT AQA drink Operating Instructions Manual page 34

Advertisement

Available languages

Available languages

BWT system hygiene
Each BWT AQA drink Pro 60 water dispenser is equipped with the BWT system hygiene. In this special 3-
fold protection, well thought-out technology and product solutions interlock in perfectly coordinated
processes.
» Ultrafiltration at the inlet: It is recommended to use a BWT AQA drink filter with an ultrafiltration
membrane, e.g. BWT MPC, MCS or TC filter. In this way, 99.9999% of all bacteria are retained at the
water dispenser inlet and microplastics are reduced to 0.001 mm.
» UV reactor: A state-of-the-art UV reactor directly before the water outlet prevents the system from being
contaminated with bacteria through the water outlet.
» Service: for prescribed and regular maintenance, the BWT AQA drink Pro 60 has a clever cleaning and
disinfection programme that is easy and safe to use.
3.
LOCATION AND SAFETY INSTRUCTIONS
» The cooler must be placed on a horizontal, stable surface.
» Place the dispenser in a clean, dry and well-ventilated room.
» Do not place the unit in areas exposed to direct sunlight.
» There must be a clearance of at least 100 mm behind the unit and 80 mm next to it to allow air to
circulate. Air circulation must not be obstructed!
» The water connection must have a water pressure of at least 2.5 - max. 5 bar, be of drinking water quality
and have a flow rate of at least 3 LPM (litres per minute) (see applicable drinking water regulations).
» The ambient temperature must be between 3 °C and 30 °C.
» Do not install the unit near sources of heat or open fires.
» Use indoors only!
» The installation location must be frost-proof.
» Do not store any objects on top of the device.
Caution!
If the machine has been tilted by more than 60° during transport - even if only for a short time - it must rest
for 12 hours before it can be switched on.
Chemicals, solvents and vapours must not come into contact with the device.
Do not use extension cables or multiple adapters.
3.1
OPERATING AND SAFETY INSTRUCTIONS
Every technical device requires regular maintenance and servicing (see Chapter 7) to work properly.
EN
Compliance with all safety and handling instructions provided is a fundamental requirement for safe
operation. In addition, the local accident prevention regulations and general safety regulations valid at the
location of the device apply.
Danger due to electricity!
Before performing maintenance work on this device, it must be disconnected from the mains supply.
It must be possible to disconnect the electric current either by pulling out the power cable or by means of a
biploar mains switch at the socket.
If the power cable is damaged, it must be replaced by the manufacturer or a qualified technician.
Do not use extension cables or multiple adapters.