Table 1-7. System Messages (continued)
Message
Manufacturing mode
detected
MEMBIST failure -
The following
DIMM/rank has been
disabled by BIOS:
DIMM x Rank y
Memory address
line failure at
address , read
value expecting
value
Memory double word
logic failure at
address , read
value expecting
value
Memory odd/even
logic failure at
address, read
value expecting
value
Memory write/read
failure at
address , read
value expecting
value
Memory tests
terminated by
keystroke.
Causes
System is in
manufacturing mode.
Faulty memory module(s). See "Troubleshooting
Faulty or improperly
installed memory modules.
POST memory test
terminated by pressing the
spacebar.
Corrective Actions
Reboot to take the system
out of manufacturing mode.
System Memory" on
page 142.
See "Troubleshooting
System Memory" on
page 142.
Information only.
About Your System