Table 1-6. LCD Status Messages (continued)
Code
Text
E201E POST Mem Test BIOS POST memory test
E201F DRAC Config
E2020 CPU Config
E2021 Memory
Population
E2022 POST Fail
E2110 MBE Crd #
DIMM ## & ##
Causes
failure.
Dell remote access
controller (DRAC)
configuration failure.
CPU configuration failure. Check screen for specific
Incorrect memory
configuration. Memory
population order incorrect.
General failure after video. Check screen for specific
One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE). If
no memory card is present,
the "Crd #" string is left
out of the message.
Corrective Actions
See "Troubleshooting
System Memory" on
page 142. If problem
persists, see "Getting Help"
on page 167.
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If problem
persists, see your DRAC
documentation.
error messages.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 142.
error messages.
See "Troubleshooting
System Memory" on
page 142.
About Your System
29

Advertisement

Table of Contents