Troubleshooting a Damaged System

Problem
System was dropped or damaged.
Action
CAUTION:
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
1 Open the system. See "Opening and Closing the System" on page 66.
2 Ensure that the following components are properly installed:
Expansion cards and risers
Power supplies
Fans
Processors and heat sinks
Memory modules
Drive-carrier connections to the SAS backplane board, if applicable
3 Ensure that all cables are properly connected.
4 Close the system. See "Opening and Closing the System" on page 66.
5 Run the system board tests in the system diagnostics. See "Running the
System Diagnostics" on page 154.
If the tests fail, see "Getting Help" on page 167.

Troubleshooting the System Battery

Problem
System message indicates a problem with the battery.
System Setup program loses system configuration information.
System date and time do not remain current.