Table 1-6. LCD Status Messages (continued)
Code
Text
E1414 CPU #
Thermtrip
E1418 CPU #
Presence
E141C CPU Mismatch
Causes
Specified microprocessor
is out of acceptable
temperature range and has
halted operation.
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
Processors are in a
configuration unsupported
by Dell.
Corrective Actions
See "Troubleshooting
System Cooling Problems"
on page 140. If the problem
persists, ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 150.
NOTE:
The LCD continues to
display this message until the
system's power cord is
disconnected and
reconnected to the AC power
source, or the SEL is cleared
using either Server Assistant
or the BMC Management
Utility. See the Dell
OpenManage Baseboard
Management Controller
User's Guide for information
about these utilities.
See "Troubleshooting the
Microprocessors" on
page 150.
Ensure that your
processors match and
conform to the type
described in the
Microprocessor Technical
Specifications outlined in
your system's Getting
Started Guide.
About Your System