Table 1-6. LCD Status Messages (continued)
Code
Text
E1712 PCI SERR B##
D## F##
PCI SERR Slot
#
E1714 Unknown Err
E171F PCIE Fatal
Err B## D##
F##
PCIE Fatal
Err Slot #
E1810 HDD ## Fault
26
About Your System
Causes
The system BIOS has
reported a PCI system
error on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
The system BIOS has
reported a PCI system
error on a component that
resides in the specified
slot.
The system BIOS has
determined that there has
been an error in the
system, but is unable to
determine its origin.
The system BIOS has
reported a PCIe fatal error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
The system BIOS has
reported a PCIe fatal error
on a component that
resides in the specified
slot.
The SAS subsystem has
determined that hard drive
## has experienced a
fault.
Corrective Actions
Remove and reseat the
PCI expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.
Reinstall the expansion-
card cage. See "Expansion-
Card Cage" on page 91.
If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 167.
See "Getting Help" on
page 167.
Remove and reseat the
PCI expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.
Reinstall the expansion-
card cage. See "Expansion-
Card Cage" on page 91.
If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 167.
See "Troubleshooting a
Hard Drive" on page 146.

Advertisement

Table of Contents
loading

Table of Contents