Table 1-6. LCD Status Messages (continued)
Code
Text
E1620 PS # Input
Range
E1624 PS Redundancy The power supply
E1710 I/O Channel
Chk
E1711 PCI PERR B##
D## F##
PCI PERR Slot
#
Causes
Power source for specified
power supply is
unavailable, or out of
acceptable range.
subsystem is no longer
redundant. If the last
supply fails, the system will
go down.
The system BIOS has
reported an I/O channel
check.
The system BIOS has
reported a PCI parity error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.
The system BIOS has
reported a PCI parity error
on a component that
resides in the specified
PCI slot.
Corrective Actions
Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 139.
See "Troubleshooting
Power Supplies" on
page 139.
See "Getting Help" on
page 167.
Remove and reseat the
PCI expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.
Reinstall the expansion-
card cage. See "Expansion-
Card Cage" on page 91.
If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 167.