Dell PowerVault DL2000 Hardware Owner's Manual page 27

Dell storage system hardware owner's manual
Hide thumbs Also See for PowerVault DL2000:
Table of Contents

Advertisement

Table 1-6. LCD Status Messages (continued)
Code
Text
E1811 HDD ## Rbld
Abrt
E1812 HDD ##
Removed
E1913 CPU &
Firmware
Mismatch
E1A11 PCI Rsr
Config
E1A12 PCI Rsr
Missing
E1A14 SAS Cable A
E1A15 SAS Cable B
E2010 No Memory
Causes
The specified hard drive
has experienced a rebuild
abort.
The specified hard drive
has been removed from
the system.
The BMC firmware does
not support the CPU.
PCI risers are not
configured correctly; some
invalid configurations may
prevent the system from
powering on.
One or all of the PCI risers
is missing, preventing the
system from powering on.
SAS cable A is missing or
bad.
SAS cable B is missing or
bad.
No memory is installed in
the system.
Corrective Actions
See "Troubleshooting a
Hard Drive" on page 146.
If the problem persists, see
your RAID
documentation.
Information only.
Update to the latest BMC
firmware. See the BMC
User's Guide for more
information on setup and
use of BMC.
See "Expansion-Card Riser
Boards" on page 112.
Information only.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Daughter Card" on
page 85.
Reseat the cable. If
problem persists, replace
cable. See "SAS Controller
Daughter Card" on
page 85.
Install memory. See
"Installing Memory
Modules" on page 102.