Catalyst 1900 And Catalyst 2820 Cli Considerations; Using Snmp To Manage Switch Clusters - Cisco WS-C3560-48PS-S Software Configuration Manual

Software configuration guide
Hide thumbs Also See for WS-C3560-48PS-S:
Table of Contents

Advertisement

Using SNMP to Manage Switch Clusters

Catalyst 1900 and Catalyst 2820 CLI Considerations

If your switch cluster has Catalyst 1900 and Catalyst 2820 switches running standard edition software,
the Telnet session accesses the management console (a menu-driven interface) if the cluster command
switch is at privilege level 15. If the cluster command switch is at privilege level 1 to 14, you are
prompted for the password to access the menu console.
Command-switch privilege levels map to the Catalyst 1900 and Catalyst 2820 cluster member switches
running standard and Enterprise Edition Software as follows:
The Catalyst 1900 and Catalyst 2820 CLI is available only on switches running Enterprise Edition
Note
Software.
For more information about the Catalyst 1900 and Catalyst 2820 switches, refer to the installation and
configuration guides for those switches.
Using SNMP to Manage Switch Clusters
When you first power on the switch, SNMP is enabled if you enter the IP information by using the setup
program and accept its proposed configuration. If you did not use the setup program to enter the IP
information and SNMP was not enabled, you can enable it as described in the
section on page
When you create a cluster, the cluster command switch manages the exchange of messages between
cluster member switches and an SNMP application. The cluster software on the cluster command switch
appends the cluster member switch number (@esN, where N is the switch number) to the first configured
read-write and read-only community strings on the cluster command switch and propagates them to the
cluster member switch. The cluster command switch uses this community string to control the
forwarding of gets, sets, and get-next messages between the SNMP management station and the cluster
member switches.
Note
When a cluster standby group is configured, the cluster command switch can change without your
knowledge. Use the first read-write and read-only community strings to communicate with the cluster
command switch if there is a cluster standby group configured for the cluster.
If the cluster member switch does not have an IP address, the cluster command switch redirects traps
from the cluster member switch to the management station, as shown in
switch has its own IP address and community strings, the cluster member switch can send traps directly
to the management station, without going through the cluster command switch.
If a cluster member switch has its own IP address and community strings, they can be used in addition
to the access provided by the cluster command switch. For more information about SNMP and
community strings, see
Catalyst 3560 Switch Software Configuration Guide
5-22
If the command-switch privilege level is 1 to 14, the cluster member switch is accessed at privilege
level 1.
If the command-switch privilege level is 15, the cluster member switch is accessed at privilege level
15.
26-6. On Catalyst 1900 and Catalyst 2820 switches, SNMP is enabled by default.
Chapter 26, "Configuring SNMP."
Chapter 5
Clustering Switches
"Configuring SNMP"
Figure
5-13. If a cluster member
78-16156-01