11. TROUBLESHOOTING

11-1. Display and Countermeasure when an Error Occurred

Error
Name
monitor
"SE 1" or
Sensor
"SE 2"
disconnected
LED is
error *1
ON
"SE 1" or
Sensor data
"SE 2"
error *1
LED blinks
"PF" LED
Low power
is ON
supply error
"ME" LED
Memory error
Is ON
"WSP"
Converter
LED is ON
error
"WSP"
Converter
LED blinks
error
*1: The sensor disconnected error would be displayed, if both the sensor disconnected error and sensor data error
are occurred at the same time.
Note
The error wouldn't be cleared if a cause isn't removed.

11-2. Error Clear Method

The error clear is executed by following methods.
(1) In the case of clearing SE and PE
・ Press the error clear button [CLR] on the front panel.
・ Turn on the error clear input signal [CLR]
in the I/O connector from PLC or host controller.
(2) In the case of clearing ME
・ Press both zero point setting buttons [ZPS1 and ZPS2 ] on the front panel at the same time.
Probable cause
Sensor connector is disconnected
or loose.
Sensor cable is severed.
ABSOCODER sensor failure
Converter failure
Sensor connector is loose.
ABSOCODER sensor was
shocked excessively.
Wiring has a noise source
Sensor cable is severed.
Voltage drop of the power supply.
Instantaneous power failure of
the power supply.
Memory data has been changed
due to external noise, etc.
Watchdog timer error occurs.
Converter failure
Error cancel procedures
After removing an error cause, clear the error by
either way:
- Press CLR button.
- Turn ON the error clear input signal.
Replace the sensor cable.
Replace the ABSOCODER sensor.
Replace the converter.
After removing an error cause, clear the error by
either way:
- Press CLR button.
- Turn ON the error clear input signal.
Replace the sensor cable.
After removing an error cause, clear the error by
either way:
- Press CLR button.
- Turn ON the error clear input signal.
After moving the machine to the zero point, press
"ZPS1" and "ZPS2" buttons at same time in order to
clear an error.
NOTE
The position data is changed to "0" when clearing
the error. (The zero point setting is executed.)
Replace the converter.
Replace the converter.
Error clear button
Zero point setting button
41