Motors-Drive
Voltage:
Standard motors are multi-voltage
Low Voltage:
High Voltage:
208-240V 1Phase Wiring Diagram
To reverse motor rotation interchange yellow and orange leads.
Motor 1/6 HP
208/240V
Run
Winding
Run X
Winding
380/480/575/V 3Phase Wiring Diagram
To reverse motor rotation interchange any two external connections.
Motor 1/6HP
380/480/575 Volt
Conveyor Drive Jam Switch
• The conveyor jam switch stops the conveyor if something obstructs the movement of
of the rack conveyor.
• The light on the green start switch goes out and the pumps and the conveyor drive
motor stop running.
• After clearing the jam, push the green start button and insert another dishrack to
restart the pumps and conveyor. Be sure to wash any dishracks that may have been
stalled in the dishwasher prior to the jam condition.
208-240VAC
380/480/575VAC
White Wire
Capacitor
10MFD
370VAC
Orange Wire
Start
Winding
Yellow WIre
Connect 208/240 V
Brown Wire
Power Here
Black Wire
Red Wire
P6 Orange Wire
P5 Tan Wire
P4 Blue Wire
T6 Purple Wire
T9 Brown Wire
T4 Yellow Wire
T7 Pink Wire
T5 Black Wire
T8 Red Wire
T3 Orange Wire
T1 Blue Wire
T2 Tan Wire
Basic Service • Electrical
1 Phase Only
3 Phase Only
Connect 380/480/575 V
3 Phase
Power Here