1. Use a qualified detergent/chemical supplier for
detergent/chemical and dispensing equipment needs.
2. Labeled detergent control circuit connection terminals
are provided in the control cabinet for detergent and
rinse agent/sanitizer dispensing equipment (supplied by
others).
3. The illustration on the right, shows the terminal board
for the current production machines .
The signal connection points include:
• Detergent signal 120VAC, 1Amp max amp load
• Rinse aid/Sanitizer signal 120VAC, 1Amp max amp
load
4. A removable black plug is provided in the load end side of the wash
tank (behind the drive motor) for installation of the detergent
conductivity cell.
1. Refer to the illustrations below and hang the curtains as shown.
J-hooks are located in the corners of each section to accept the curtain rods.
Standard long curtains
High hood long curtains
Standard short curtains
High hood short curtains
Final rinse curtain
2. Make sure the that the short flaps of the curtains face the load end of the dishwasher. The
longest curtains always go on each end of the dishwasher.
24" x 20-1/4"
24" x 22-3/4"
24" x 13-/14"
24" x 20-1/4"
24" x 6-1/4"