7.8 Water fault finding

Fault
Water not flowing
from any tap when
operated but pump
runs
Pump does not run
48
Cause
Freshwater tank empty
Pump wired in reverse
Pipe inlet or outlet pipe
disconnected
Pump pipes restricted by kinking
Blockage in pump inlet or outlet
pipe
Blocked pump filter
Air leak in suction line
to pump
Pump incorrectly wired
Pump fuse blown
Battery disconnected
Pump seized or overheated
Pressure pump sensing switch may
have failed
Contacts may be faulty
Wiring connections may be faulty
Remedy
Check
Check wiring, refer to pump
manufacturers instructions
Check connections
Check pipes run
Check, starting inside freshwater
tank
Dismantle and clean filter. See
pump manufactures instructions.
Check condition of pipe and pipe
joints between the water tank and
the pump.
Refer to pump manufacturers
instructions
Check wiring connection and then
replace with fuse of correct rating
Check connections
Refer to pump manufacturers
servicing instructions
Refer to pump manufacturers
servicing instructions
Check contacts in plug and socket
are clean and making contact
Check wiring connections