8.4 Common Fault Table
Fault
No 230-volt output
from MC200
Reverse Polarity
light is illuminated
on MC200
78
Possible Cause Proposed Fix
Connecting lead
Check and connect lead.
between the site
and Leisure Vehicle
not connected
RCD switched off
Reset RCD
RCD not operating
Check supply polarity; if the RCD continues to
correctly
fail contact your Dealer as there is probably an
equipment or wiring fault.
MCB switched off
Reset MCB by switching OFF (down position)
then back ON (up position), if the MCB continues
to fail contact your Dealer as there is probably an
equipment or wiring fault.
No or deficient
Contact site Warden for assistance.
supply from site
Another fault
Contact your Dealer.
Mains Supply
The reverse polarity light is designed to illuminate
reversed?
when the Live and Neutral supply has been reversed
/ crossed over. If the light illuminates there is a
problem with the site supply or the cable connecting
the supply to your vehicle. The light is designed to
work on UK electrical supplies (where the neutral
conductor is connected to earth at the substation).
If you are using your vehicle outside the UK this light
may illuminate when no fault exists. In these cases,
consult the site warden for advice
Generator being
'The Reverse Polarity warning light is on when using
used
my Generator'.
This is a normal side effect when using some types
of generators. Instead of connecting the neutral
conductor to earth, some generators centre-tap
the earth connection making both neutral and live
conductors 110V above earth. This 110V difference
causes the neon polarity indicator to illuminate. In
most cases it is still safe to use the generator, but
please consult the generator handbook for further
information.
Need help?