ADF Web HD67675-IP-A1 User Manual

ADF Web HD67675-IP-A1 User Manual

Bacnet slave / profibus master - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.010
English
BACnet slave / PROFIBUS master -
Converter
(Order Code: HD67675-IP-A1, HD67675-MSTP-A1,
HD67675-PTP-A1)
For Website information:
www.adfweb.com/?Product=HD67675
For Price information:
www.adfweb.com/?Price=HD67675-IP-A1
www.adfweb.com/?Price=HD67675-MSTP-A1
www.adfweb.com/?Price=HD67675-PTP-A1
Benefits and Main Features:
Very easy to configure
PROFIBUS DP-V0 up to 6Mbps
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual BACnet slave / PROFIBUS master - Converter
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
Axis Solutions Pvt Ltd is the Authorized Distributor of
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
www.axisindia.in | info@axisindia.in
Document code: MN67675_ENG
Revision 1.010
For others PROFIBUS products see also the following link:
PROFIBUS Master from/to ...
www.adfweb.com?Product=HD67570
www.adfweb.com?Product=HD67575
www.adfweb.com?Product=HD67577
www.adfweb.com?Product=HD67579
www.adfweb.com?Product=HD67580
EtherNet/IP from/to ...
www.adfweb.com?Product=HD67077
www.adfweb.com?Product=HD67589
www.adfweb.com?Product=HD67590
www.adfweb.com?Product=HD67591
www.adfweb.com?Product=HD67592
www.adfweb.com?Product=HD67594
www.adfweb.com?Product=HD67595
www.adfweb.com?Product=HD67597
www.adfweb.com?Product=HD67598
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
in India
in India
in India
in India
Page 1 of 40
(... DeviceNet Slave)
(... Ethernet)
(... CAN)
(... Modbus TCP Slave)
(... Modbus Slave)
(... M-Bus)
(... NMEA 2000)
(... Serial)
(... Modbus Master)
(... Modbus Slave)
(... PROFIBUS Slave)
(... CAN)
(... DeviceNet Master)
(... DeviceNet Slave)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67675-IP-A1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67675-IP-A1

  • Page 1 Page 1 of 40 Industrial Electronic Devices User Manual Revision 1.010 English BACnet slave / PROFIBUS master - Converter (Order Code: HD67675-IP-A1, HD67675-MSTP-A1, HD67675-PTP-A1) For Website information: www.adfweb.com/?Product=HD67675 For Price information: For others PROFIBUS products see also the following link: www.adfweb.com/?Price=HD67675-IP-A1 www.adfweb.com/?Price=HD67675-MSTP-A1...
  • Page 2: Table Of Contents

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 2 of 40 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page INDEX Dear customer, we thank you for your attention and we remind you that UPDATED DOCUMENTATION you need to check that the following document is: REVISION LIST Updated...
  • Page 3: Security Alert

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 3 of 40 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Examples Of Connection

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 4 of 40 Industrial Electronic Devices EXAMPLES OF CONNECTION: ADFweb.com S.r.l.
  • Page 5 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 5 of 40 Industrial Electronic Devices ADFweb.com S.r.l.
  • Page 6: Connection Scheme

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 6 of 40 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67675-IP-A1 ADFweb.com S.r.l.
  • Page 7 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 7 of 40 Industrial Electronic Devices Figure 1b: Connection scheme for HD67675-MSTP-A1 ADFweb.com S.r.l.
  • Page 8 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 8 of 40 Industrial Electronic Devices Figure 1c: Connection scheme for HD67675-PTP-A1 ADFweb.com S.r.l.
  • Page 9: Characteristics

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 9 of 40 Industrial Electronic Devices CHARACTERISTICS: The HD67675-xxx-A1 are BACnet slave / PROFIBUS master Converter. It allows the following characteristics: Triple isolation between BACnet/PROFIBUS, BACnet/Power Supply, PROFIBUS/Power Supply; Two-directional information between BACnet and PROFIBUS bus;...
  • Page 10: Power Supply

    The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD67675-A1 Consumption at 24V DC: Device W/VA HD67675-IP-A1 HD67675-MSTP-A1 HD67675-PTP-A1 Caution: Do not reverse the polarity power HD67675-IP-A1 HD67675-MSTP-A1 HD67675-PTP-A1 ADFweb.com S.r.l.
  • Page 11: Function Modes

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 11 of 40 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip2 of ‘Dip-Switch A’: The first, with Dip2 at “OFF”...
  • Page 12: Leds

    Revision 1.010 Page 12 of 40 Industrial Electronic Devices LEDS (for HD67675-IP-A1): The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below.
  • Page 13 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 13 of 40 Industrial Electronic Devices LEDS (for HD67675-MSTP-A1 and HD67675-PTP-A1): The device has got five LEDs that are used to give information about the functioning status. The various meanings of the LEDs are described in the table below.
  • Page 14: Profibus

    ETHERNET: The BACnet/IP connection and the updating of the Converter must be made using Connector3 and/or Connector4 of HD67675-IP-A1 or Connector4 of HD67675-MSTP- A1/HD67675-PTP-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps.
  • Page 15: Rs232

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 15 of 40 Industrial Electronic Devices RS232 (HD67675-PTP-A1): The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a NULL MODEM cable (a serial cable where the pins 2 and 3 are crossed).
  • Page 16: Rs485

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 16 of 40 Industrial Electronic Devices RS485 (HD67675-MSTP-A1): To terminate the RS485 line with a 220Ω resistor it is necessary to put ON dip 1, like in figure. The maximum length of the cable should be 1200m (4000 feet).
  • Page 17: Use Of Compositor Sw67675

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 17 of 40 Industrial Electronic Devices USE OF COMPOSITOR SW67675: To configure the Converter, use the available software that runs with Windows called SW67675. It is downloadable from the site www.adfweb.com and its operation is described in this document (this manual is referenced to the last version of the software present on the web site).
  • Page 18: New Configuration / Open Configuration

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 18 of 40 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “BACnet slave / PROFIBUS master - Converter”...
  • Page 19: Software Options

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 19 of 40 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 20: Set Communication

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 20 of 40 Industrial Electronic Devices SET COMMUNICATION: This section defines the fundamental communication parameter of two buses, PROFIBUS and BACnet. By pressing the “Set Communication”...
  • Page 21 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 21 of 40 Industrial Electronic Devices If selected “BACnet MS/TP” or “BACnet PTP” the means of the fields for “BACnet” are: In the field “Baudrate” it is possible to select the baudrate of the BACnet line (1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200);...
  • Page 22: Profibus Network

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 22 of 40 Industrial Electronic Devices PROFIBUS NETWORK: By pressing the “PROFIBUS Network” button from the main window for SW67675 (Fig. 2) the window “PROFIBUS Network” (Fig. 4) appears.
  • Page 23: Master Profibus Options

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 23 of 40 Industrial Electronic Devices MASTER PROFIBUS OPTIONS: By pressing the “Master PROFIBUS Options” button from the “PROFIBUS Network” window (Fig. 4) the “PROFIBUS Master Options” window appears (Fig.
  • Page 24: Profibus Device

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 24 of 40 Industrial Electronic Devices PROFIBUS DEVICE: By pressing the “Add Slave PROFIBUS” and “Modify Slave PROFIBUS” button (or double click above an existent PROFIBUS Slave) from the “PROFIBUS Network”...
  • Page 25: Module Selection

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 25 of 40 Industrial Electronic Devices ODULE ELECTION The section “Module Selection” is used to select which Modules are present in the Slave (Fig. 7). In this section is possible to: Check the list of the Modules selected (“Select Modules”) (Fig.
  • Page 26 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 26 of 40 Industrial Electronic Devices By pressing the “Manual Module” button from the “PROFIBUS Device” window (Fig. 6) the “Add Module Manually” window appears (Fig. 8). In this window is possible to add a Module manually, i.e.
  • Page 27: User Parameters

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 27 of 40 Industrial Electronic Devices ARAMETERS The section “User Parameters” is used to modify the parameters of the PROFIBUS slave (Fig. 9). In this section there are: The List of all Parameters available for the PROFIBUS device (“User Parameters”) (Fig.
  • Page 28 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 28 of 40 Industrial Electronic Devices By pressing the “Modify User Parameters Manually” button from the “PROFIBUS Device” window (Fig. 6) the “Add Module Manually” window appears (Fig.
  • Page 29: Module Parameters

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 29 of 40 Industrial Electronic Devices ODULE ARAMETERS The section “Module Parameters” is used to modify the parameters of the Modules (Fig. 11). In this section there are: The List of all Module selected in the GSD file (“Available modules”) (Fig.
  • Page 30: Capabilities

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 30 of 40 Industrial Electronic Devices APABILITIES The section “Capabilities” is used only to show which features/baudrates available in the PROFIBUS device. The Green Icon indicate that capability/baudrate is available, the Red Icon indicate no compatibilities with that capability/baudrate (Fig.
  • Page 31: Options

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 31 of 40 Industrial Electronic Devices PTIONS The section “Options” is used to enable some option for each PROFIBUS device (Fig. 13). The means of the fields are: field “Enable Sync”...
  • Page 32: Set Bacnet Access

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 32 of 40 Industrial Electronic Devices SET BACNET ACCESS: By Pressing the “Set BACnet Access ” button from the “PROFIBUS Network” window (Fig. 4) the window “Set BACnet Access” appears (Fig. 14).
  • Page 33: Bacnet Access

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 33 of 40 Industrial Electronic Devices Is possible to insert directly the Unit (using its unique number) by compiling the “Selected BACnet Engineering Unit” field; or by selecting with the fields “Select Type”...
  • Page 34: Update Device

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 34 of 40 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created configuration into the device; and also the firmware, if necessary. If you don’t know the actual IP address of the device you have to use this procedure: Turn off the Device;...
  • Page 35 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 35 of 40 Industrial Electronic Devices If you know the actual IP address of the device, you have to use this procedure: Turn on the Device with the Ethernet cable inserted; Insert the actual IP of the Converter;...
  • Page 36: Mechanical Dimensions

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 36 of 40 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 18a: Mechanical dimensions scheme for HD67675-IP-A1 ADFweb.com S.r.l.
  • Page 37 User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 37 of 40 Industrial Electronic Devices Figure 18b: Mechanical dimensions scheme for HD67675-MSTP-A1 Figure 18c: Mechanical dimensions scheme for HD67675-PTP-A1 ADFweb.com S.r.l.
  • Page 38: Ordering Informations

    IP: BACnet/IP MSTP: BACnet MS/TP PTP: BACnet PTP Device Family HD67675: BACnet slave / PROFIBUS master- Converter Order Code: HD67675-IP-A1 BACnet/IP slave / PROFIBUS master – Converter Order Code: HD67675-MSTP-A1 BACnet MS/TP slave / PROFIBUS master – Converter Order Code: HD67675-PTP-A1...
  • Page 39: Disclaimer

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 39 of 40 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 40: Warranties And Technical Support

    User Manual BACnet slave / PROFIBUS master - Converter Document code: MN67675_ENG Revision 1.010 Page 40 of 40 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

This manual is also suitable for: