EtherNet/IP Master / PROFIBUS Slave -
Converter
(Order Code: HD67643-A1)
for Website information:
http://www.adfweb.com/?Product=HD67643
for Price information:
http://www.adfweb.com/?Price=HD67643-A1
Benefits and Main Features:
Triple electrical isolation
Two Ethernet ports
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual EtherNet/IP Master / PROFIBUS Slave
Document code: MN67643_ENG
For others EtherNet/IP Master devices, see also the following links:
EtherNet/IP Master from/to ...
www.adfweb.com?Product=HD67158
www.adfweb.com?Product=HD67643
www.adfweb.com?Product=HD67645
www.adfweb.com?Product=HD67646
www.adfweb.com?Product=HD67647
www.adfweb.com?Product=HD67661
www.adfweb.com?Product=HD67665
www.adfweb.com?Product=HD67667
www.adfweb.com?Product=HD67669
www.adfweb.com?Product=HD67689
www.adfweb.com?Product=HD67806
www.adfweb.com?Product=HD67955
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Revision 1.000
Page 1 of 24
(SNMP Agent)
(PROFIBUS Slave)
(CAN)
(CANopen)
(DeviceNet Slave)
(PROFINET)
(Modbus TCP Slave)
(Serial)
(Modbus Slave)
(BACnet Slave)
(KNX)
(MQTT)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67643-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67643-A1

  • Page 1 Industrial Electronic Devices User Manual Revision 1.000 English EtherNet/IP Master / PROFIBUS Slave - Converter (Order Code: HD67643-A1) for Website information: http://www.adfweb.com/?Product=HD67643 for Price information: http://www.adfweb.com/?Price=HD67643-A1 For others EtherNet/IP Master devices, see also the following links: EtherNet/IP Master from/to …...
  • Page 2: Table Of Contents

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 2 of 24 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 3 of 24 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 4 of 24 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 5 of 24 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67643-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6: Characteristics

    Page 6 of 24 Industrial Electronic Devices CHARACTERISTICS: The HD67643-A1 is a EtherNet/IP Master / PROFIBUS slave Converter. It allows the following characteristics: Two-directional information between EtherNet/IP and PROFIBUS; Electrical isolation between PROFIBUS – EtherNet/IP, Power Supply – EtherNet/IP, Power Supply – PROFIBUS;...
  • Page 7: Power Supply

    POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD67643-A1 Consumption at 24V DC: Device W/VA HD67643-A1 Caution: Not reverse the polarity power HD67643-A1 ADFweb.com Srl –...
  • Page 8: Function Modes

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 8 of 24 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip2 of ‘Dip-Switch A’: The first, with Dip2 in Off position (factory setting), is used for the normal working of the device. The second, with Dip2 in On position, is used for upload the Project/Firmware.
  • Page 9: Leds

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 9 of 24 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10: Profibus

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 10 of 24 Industrial Electronic Devices PROFIBUS: The PROFIBUS uses a 9-pin D-SUB connector. The pin assignment is defined like in the following figure. Here some codes of cables: Belden: p/n 183079A - Continuous Armor DataBus®...
  • Page 11: Ethernet

    ETHERNET: The Ethernet connection must be made using Connector3 or Connector4 of HD67643-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is recommended the use of a cross cable.
  • Page 12: Use Of Compositor Sw67643

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 12 of 24 Industrial Electronic Devices USE OF COMPOSITOR SW67643: To configure the Converter, use the available software that runs with Windows called SW67643. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 13: New Project / Open Project

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 13 of 24 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “EtherNet/IP Master / PROFIBUS Slave - Converter”...
  • Page 14: Software Options

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 14 of 24 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 15 User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 15 of 24 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 16: Set Communication

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 16 of 24 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, PROFIBUS and EtherNet/IP. By Pressing the “Set Communication” button from the main window for SW67643 (Fig.
  • Page 17: Ethernet/Ip Access

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 17 of 24 Industrial Electronic Devices ETHERNET/IP ACCESS: By Pressing the “EtherNet/IP Access” button from the main window for SW67643 (Fig. 2) the window “Set EtherNet/IP Slaves Access” appears (Fig.
  • Page 18: Gsd File

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 18 of 24 Industrial Electronic Devices GSD FILE: By pressing the “PROFIBUS GSD” button it is possible to save the GSD file for the PROFIBUS side. With this feature you can save the configuration of the gateway of the PROFIBUS side. Note: When you import the .gsd file on your Master PROFIBUS you have to add all the modules that are present inside it in the correct order.
  • Page 19: Update Device

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 19 of 24 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 20 User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 20 of 24 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67643 device. Warning: If Fig.
  • Page 21: Mechanical Dimensions

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 21 of 24 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7: Mechanical dimensions scheme for HD67643-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 22: Ordering Informations

    Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family HD67643 Ethernet/IP Master / PROFIBUS Slave - Converter Order Code: HD67643-A1 Ethernet/IP Master / PROFIBUS Slave - Converter ACCESSORIES: Order Code: AC34011 Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 23: Disclaimer

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 23 of 24 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 24: Warranties And Technical Support

    User Manual EtherNet/IP Master / PROFIBUS Slave Document code: MN67643_ENG Revision 1.000 Page 24 of 24 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents