ADF Web HD67618-A1 User Manual

ADF Web HD67618-A1 User Manual

S7comm / modbus tcp slave - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
S7comm / Modbus TCP Slave - Converter
(Order Code: HD67618-A1)
for Website information:
http://www.adfweb.com/?Product=HD67618
for Price information:
http://www.adfweb.com/?Price=HD67618-A1
Benefits and Main Features:
Triple electrical isolation
Two Ethernet ports
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual S7comm / Modbus TCP Slave
Document code: MN67618_ENG
Revision 1.000
For others S7comm devices, see also the following links:
S7comm from/to ...
www.adfweb.com?Product=HD67619
www.adfweb.com?Product=HD67620
www.adfweb.com?Product=HD67621
www.adfweb.com?Product=HD67622
www.adfweb.com?Product=HD67623
www.adfweb.com?Product=HD67624
www.adfweb.com?Product=HD67625
www.adfweb.com?Product=HD67626
www.adfweb.com?Product=HD67627
www.adfweb.com?Product=HD67628
www.adfweb.com?Product=HD67629
www.adfweb.com?Product=HD67630
www.adfweb.com?Product=HD67631
www.adfweb.com?Product=HD67632
www.adfweb.com?Product=HD67633
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Page 1 of 25
(PROFIBUS Slave)
(IEC61850 Server)
(Serial)
(Modbus Slave)
(CAN)
(CANopen)
(DeviceNet Slave)
(SNMP Agent)
(EtherNet/IP Slave)
(KNX)
(MQTT)
(BACnet Slave)
(Ethernet)
(OPC UA Server)
(PROFINET Slave)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading

Summary of Contents for ADF Web HD67618-A1

  • Page 1 Page 1 of 25 Industrial Electronic Devices User Manual Revision 1.000 English S7comm / Modbus TCP Slave - Converter (Order Code: HD67618-A1) for Website information: http://www.adfweb.com/?Product=HD67618 for Price information: http://www.adfweb.com/?Price=HD67618-A1 For others S7comm devices, see also the following links: S7comm from/to …...
  • Page 2: Table Of Contents

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 2 of 25 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 3 of 25 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 4 of 25 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 5 of 25 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67618-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6: Characteristics

    Revision 1.000 Page 6 of 25 Industrial Electronic Devices CHARACTERISTICS: The HD67618-A1 is a S7comm / Modbus TCP slave Converter. It allows the following characteristics: Two-directional information between S7comm and Modbus TCP; Mountable on 35mm Rail DIN; Wide power supply input range: 8…24V AC or 12…35V DC;...
  • Page 7: Power Supply

    POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD67618-A1 Consumption at 24V DC: Device W/VA HD67618-A1 Caution: Not reverse the polarity power HD67618-A1 ADFweb.com Srl –...
  • Page 8: Function Modes

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 8 of 25 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip1 of ‘Dip-Switch A’: The first, with Dip1 in Off position (factory setting), is used for the normal working of the device. The second, with Dip1 in On position, is used for upload the Project/Firmware.
  • Page 9: Leds

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 9 of 25 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10: Ethernet

    ETHERNET: The Ethernet connection must be made using Connector3 or Connector4 of HD67618-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is recommended the use of a cross cable.
  • Page 11: Use Of Compositor Sw67618

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 11 of 25 Industrial Electronic Devices USE OF COMPOSITOR SW67618: To configure the Converter, use the available software that runs with Windows called SW67618. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 12: New Project / Open Project

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 12 of 25 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “S7comm / Modbus TCP Slave - Converter”...
  • Page 13: Software Options

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 13 of 25 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 14 User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 14 of 25 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 15: Set Communication

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 15 of 25 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, Modbus TCP and S7comm. By Pressing the “Set Communication” button from the main window for SW67618 (Fig. 2) the window “Set Communication”...
  • Page 16: S7 Protocol Access

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 16 of 25 Industrial Electronic Devices S7 PROTOCOL ACCESS: By Pressing the “S7 Protocol Access ” button from the main window of SW67618 (Fig. 2), the window “Set S7comm Access” appears (Fig. 4).
  • Page 17 User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 17 of 25 Industrial Electronic Devices In the field “Start Bit” is used for the “Bit” data. It is possible to select the bit of the selected Position where mapping the data; If the field “Swap”...
  • Page 18 User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 18 of 25 Industrial Electronic Devices Figure 4b: “S7 Protocol Access  S7comm Write” window The means of the fields in the window “S7comm Read” are the following: In the field “PLC Address”...
  • Page 19: Update Device

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 19 of 25 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 20 User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 20 of 25 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67618 device. Warning: If Fig.
  • Page 21: Mechanical Dimensions

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 21 of 25 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7: Mechanical dimensions scheme for HD67618-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 22: Modbus Map

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 22 of 25 Industrial Electronic Devices MODBUS MAP: Data in reading: Type Address Function Description Input Bytes 0-1 of internal array (Position) Input Register Input Bytes 2-3 of internal array (Position) Input Register Input Bytes 4-5 of internal array (Position) Input Register...
  • Page 23: Ordering Informations

    Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family HD67618: S7comm / Modbus TCP Slave - Converter Order Code: HD67618-A1 S7comm / Modbus TCP Slave - Converter ACCESSORIES: Order Code: AC34011 Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V DC Order Code: AC34012 Rail DIN - Power Supply 220/240V AC 50/60Hz –...
  • Page 24: Disclaimer

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 24 of 25 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 25: Warranties And Technical Support

    User Manual S7comm / Modbus TCP Slave Document code: MN67618_ENG Revision 1.000 Page 25 of 25 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

Table of Contents