ADF Web HD67661-A1 User Manual

ADF Web HD67661-A1 User Manual

Profinet / ethernet/ip master - converter

Advertisement

Industrial Electronic Devices
User Manual
Revision 1.001
English
PROFINET / EtherNet/IP Master -
Converter
(Order Code: HD67661-A1)
for Website information:
http://www.adfweb.com/?Product=HD67661
for Price information:
http://www.adfweb.com/?Price=HD67661-A1
Benefits and Main Features:
Triple electrical isolation
Two Ethernet ports
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual PROFINET / EtherNet/IP Master
Document code: MN67661_ENG
For others EtherNet/IP Master devices, see also the following links:
EtherNet/IP Master from/to ...
www.adfweb.com?Product=HD67158
www.adfweb.com?Product=HD67643
www.adfweb.com?Product=HD67645
www.adfweb.com?Product=HD67646
www.adfweb.com?Product=HD67647
www.adfweb.com?Product=HD67661
www.adfweb.com?Product=HD67665
www.adfweb.com?Product=HD67667
www.adfweb.com?Product=HD67669
www.adfweb.com?Product=HD67689
www.adfweb.com?Product=HD67806
www.adfweb.com?Product=HD67955
Do you have an your customer protocol?
See the following links:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Revision 1.001
Page 1 of 26
(SNMP Agent)
(PROFIBUS Slave)
(CAN)
(CANopen)
(DeviceNet Slave)
(PROFINET)
(Modbus TCP Slave)
(Serial)
(Modbus Slave)
(BACnet Slave)
(KNX)
(MQTT)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67661-A1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67661-A1

  • Page 1 Page 1 of 26 Industrial Electronic Devices User Manual Revision 1.001 English PROFINET / EtherNet/IP Master - Converter (Order Code: HD67661-A1) for Website information: http://www.adfweb.com/?Product=HD67661 for Price information: http://www.adfweb.com/?Price=HD67661-A1 For others EtherNet/IP Master devices, see also the following links: EtherNet/IP Master from/to …...
  • Page 2: Table Of Contents

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 2 of 26 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you that you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3: Security Alert

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 3 of 26 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 4 of 26 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 5 of 26 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67661-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6: Characteristics

    Revision 1.001 Page 6 of 26 Industrial Electronic Devices CHARACTERISTICS: The HD67661-A1 is a PROFINET / EtherNet/IP Master Converter. It allows the following characteristics: Up to 1440 bytes in reading and 1440 bytes in writing; Two-directional information between EtherNet/IP and PROFINET;...
  • Page 7: Power Supply

    POWER SUPPLY: The devices can be powered between a wide range of tensions. For more details see the two tables below. Vmin Vmax Vmin Vmax HD67661-A1 Consumption at 24V DC: Device W/VA HD67661-A1 Caution: Not reverse the polarity power HD67661-A1 ADFweb.com Srl –...
  • Page 8: Function Modes

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 8 of 26 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the Dip2 of ‘Dip-Switch B’: The first, with Dip2 in Off position (factory setting), is used for the normal working of the device. The second, with Dip2 in On position, is used for upload the Project/Firmware.
  • Page 9: Leds

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 9 of 26 Industrial Electronic Devices LEDS: The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 10: Ethernet

    ETHERNET: The Ethernet connection must be made using Connector3 or Connector4 of HD67661-A1 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps. To connect the device to an Hub/Switch is recommended the use of a straight cable, to connect the device to a PC/PLC/other is recommended the use of a cross cable.
  • Page 11: Use Of Compositor Sw67661

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 11 of 26 Industrial Electronic Devices USE OF COMPOSITOR SW67661: To configure the Converter, use the available software that runs with Windows called SW67661. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 12: New Project / Open Project

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 12 of 26 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “PROFINET / EtherNet/IP Master - Converter”...
  • Page 13: Software Options

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 13 of 26 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 14 User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 14 of 26 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 15: Set Communication

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 15 of 26 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, PROFINET and EtherNet/IP. By Pressing the “Set Communication” button from the main window for SW67661 (Fig.
  • Page 16: Ethernet/Ip Access

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 16 of 26 Industrial Electronic Devices ETHERNET/IP ACCESS: By Pressing the “EtherNet/IP Access” button from the main window for SW67661 (Fig. 2) the window “Set EtherNet/IP Slaves Access” appears (Fig.
  • Page 17: Profinet Xml

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 17 of 26 Industrial Electronic Devices PROFINET XML: By pressing the “PROFINET XML” button it is possible to save the GSDML file for the PROFINET side. Figure 5: “PROFINET XML” window ADFweb.com Srl –...
  • Page 18: Update Device

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 18 of 26 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 19 User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 19 of 26 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67661 device. Warning: If Fig.
  • Page 20: Mechanical Dimensions

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 20 of 26 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 8: Mechanical dimensions scheme for HD67661-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 21: Ordering Informations

    Enclosure Type A: 1M, 35mm DIN Rail mounting Device Family HD67661: PROFINET / Ethernet/IP Master - Converter Order Code: HD67661-A1 PROFINET / Ethernet/IP Master - Converter ACCESSORIES: Order Code: AC34001 Rail DIN - Power Supply 220/240V AC 50/60Hz – 12 V AC Order Code: AC34002 Rail DIN - Power Supply 110V AC 50/60Hz –...
  • Page 22: Plc Configuration (For Profinet)

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 22 of 26 Industrial Electronic Devices PLC CONFIGURATION: The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal software by Siemens.
  • Page 23 User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 23 of 26 Industrial Electronic Devices 2) Import the module in the network; connect the device to the PLC network and edit the parameters of IP, station name etc. ADFweb.com Srl –...
  • Page 24 User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 24 of 26 Industrial Electronic Devices 3) Load the configuration into the PLC. ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 25: Disclaimer

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 25 of 26 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 26: Warranties And Technical Support

    User Manual PROFINET / EtherNet/IP Master Document code: MN67661_ENG Revision 1.001 Page 26 of 26 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

Table of Contents