ADF Web HD67672-IP-2-A1 User Manual

ADF Web HD67672-IP-2-A1 User Manual

Bacnet/ip slave / modbus slave -converter

Advertisement

Industrial Electronic Devices
User Manual
Revision 1.100
English
BACnet/IP Slave / Modbus Slave -
Converter
(Order Code: HD67672-IP-2-A1, HD67672-IP-4-A1)
BACnet MS/TP Slave / Modbus Slave -
Converter
(Order Code: HD67672-MSTP-2-A1, HD67672-MSTP-4-A1)
For Website information:
www.adfweb.com?Product=HD67672
For Price information:
www.adfweb.com?Price=HD67672-IP-2-A1
www.adfweb.com?Price=HD67672-IP-4-A1
www.adfweb.com?Price=HD67672-MSTP-2-A1
www.adfweb.com?Price=HD67672-MSTP-4-A1
Benefits and Main Features:
Very easy to configure
Electrical isolation
Temperature range: -40°C/85°C (-40°F/185°F)
User Manual
ADFweb.com Srl – IT31010 – Mareno – Treviso
User Manual BACnet Slave / Modbus Slave
Document code: MN67672_ENG
For others BACnet slave products see also the following link:
Converter BACnet to
www.adfweb.com?Product=HD67056
www.adfweb.com?Product=HD67086
www.adfweb.com?Product=HD67170
www.adfweb.com?Product=HD67670
www.adfweb.com?Product=HD67671
www.adfweb.com?Product=HD67673
www.adfweb.com?Product=HD67674
www.adfweb.com?Product=HD67675
www.adfweb.com?Product=HD67676
www.adfweb.com?Product=HD67677
www.adfweb.com?Product=HD67678
www.adfweb.com?Product=HD67679
www.adfweb.com?Product=HD67680
www.adfweb.com?Product=HD67681
www.adfweb.com?Product=HD67682
www.adfweb.com?Product=HD67683
www.adfweb.com?Product=HD67685
www.adfweb.com?Product=HD67689
www.adfweb.com?Product=HD67693
www.adfweb.com?Product=HD67802
www.adfweb.com?Product=HD67833
www.adfweb.com?Product=HD67938
Do you have an your customer protocol?
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
www.adfweb.com?Cmd=helpme
INFO:
www.adfweb.com
Revision 1.100
Pagina 1 di 32
(M-Bus Master)
(M-Bus Wireless)
(SNMP Manager)
(DMX)
(Modbus Master)
(Modbus TCP Master)
(Modbus TCP Slave)
(PROFIBUS Master)
(PROFIBUS Slave)
(CAN)
(CANopen)
(PROFINET)
(DeviceNet Master)
(DeviceNet Slave)
(EtherNet/IP Slave)
(NMEA 2000)
(J1939)
(EtherNet/IP Master)
(SNMP Agent)
(KNX)
(DALI)
(MQTT)
Phone +39.0438.30.91.31

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HD67672-IP-2-A1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67672-IP-2-A1

  • Page 1 User Manual Revision 1.100 English BACnet/IP Slave / Modbus Slave - Converter (Order Code: HD67672-IP-2-A1, HD67672-IP-4-A1) BACnet MS/TP Slave / Modbus Slave - Converter For others BACnet slave products see also the following link: (Order Code: HD67672-MSTP-2-A1, HD67672-MSTP-4-A1) Converter BACnet to www.adfweb.com?Product=HD67056...
  • Page 2: Updated Documentation

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 2 di 32 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Page Dear customer, we thank you for your attention and we remind you INDEX that you need to check that the following document is: UPDATED DOCUMENTATION Updated REVISION LIST...
  • Page 3: Security Alert

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 3 di 32 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4: Example Of Connection

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 4 di 32 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 5: Connection Scheme

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 5 di 32 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67672-IP-2-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 6 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 6 di 32 Industrial Electronic Devices Figure 1b: Connection scheme for HD67672-IP-4-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 7 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 7 di 32 Industrial Electronic Devices Figure 1c: Connection scheme for HD67672-MSTP-2-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 8 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 8 di 32 Industrial Electronic Devices Figure 1d: Connection scheme for HD67672-MSTP-4-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31...
  • Page 9 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 9 di 32 Industrial Electronic Devices CHARACTERISTICS: The HD67672 is a BACnet / Modbus Slave - Converter. It has the following characteristics: Up to 2000 BACnet objects; Triple isolation between BACnet - Power Supply, BACnet - Modbus, Power Supply - Modbus.
  • Page 10: Power Supply

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 10 di 32 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin...
  • Page 11: Function Modes

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 11 di 32 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip2 of Dip-Switch A’: The first, with ‘Dip2 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip2 of Dip-Switch A’...
  • Page 12 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 12 di 32 Industrial Electronic Devices LEDS (HD67672-IP-x-A1): The device has got six LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: Device powered...
  • Page 13 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 13 di 32 Industrial Electronic Devices LEDS (HD67672-MSTP-x-A1): The device has got four LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 14 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 14 di 32 Industrial Electronic Devices RS485: For terminate the RS485 line with a 120Ω resistor it is necessary to put ON dip 1, like in figures. The maximum length of the cable should be 1200m (4000 feet).
  • Page 15 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 15 di 32 Industrial Electronic Devices RS232: The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a NULL MODEM cable (a serial cable where the pins 2 and 3 are crossed).
  • Page 16 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 16 di 32 Industrial Electronic Devices USE OF COMPOSITOR SW67672: To configure the Converter, use the available software that runs with Windows called SW67672. It is downloadable from the site www.adfweb.com and its operation is described in this document (this manual is referenced to the last version of the software present on our web site).
  • Page 17: New Configuration / Open Configuration

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 17 di 32 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “BACnet Slave / Modbus Slave - Converter”...
  • Page 18: Software Options

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 18 di 32 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 19 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 19 di 32 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 20: Set Communication

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 20 di 32 Industrial Electronic Devices SET COMMUNICATION: This section define the fundamental communication parameters of two buses, BACnet and Modbus. By Pressing the “Set Communication” button from the main window for SW67672 (Fig. 2) the window “Set Communication”...
  • Page 21 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 21 di 32 Industrial Electronic Devices The means of the fields for the “Modbus Slave” section are: In the field “Serial” the serial port used for the Modbus communication is defined; In the field “Baudrate”...
  • Page 22 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 22 di 32 Industrial Electronic Devices If selected “BACnet MS/TP”, the means of the fields for “BACnet” are: In the field “Baudrate” the data rate of the BACnet line is defined; In the field “Parity”...
  • Page 23 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 23 di 32 Industrial Electronic Devices SET BACNET ACCESS: By Pressing the “Set BACnet Access ” button from the main window for SW67672 (Fig. 2) the window “Set Communication”...
  • Page 24 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 24 di 32 Industrial Electronic Devices Is possible to insert directly the Unit (using its unique number) by compiling the “Selected BACnet Engineering Unit” field; or by selecting with the fields “Select the Type”...
  • Page 25 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 25 di 32 Industrial Electronic Devices SET BDT ACCESS: By Pressing the “Set BDT Access ” button from the main window for SW67672 (Fig. 2) the window “Broadcast Distribution Table Access” appears (Fig.
  • Page 26: Update Device

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 26 di 32 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button it is possible to load the created Configuration into the device; and also the Firmware, if is necessary. If you don’t know the actual IP address of the device you have to use this procedure: Turn OFF the Device;...
  • Page 27 User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 27 di 32 Industrial Electronic Devices Note: When you install a new version of the software, if it is the first time it is better you do the update of the Firmware in the HD67672 device.
  • Page 28: Modbus Map

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 28 di 32 Industrial Electronic Devices MODBUS MAP: On Modbus side, the map is created automatically. In relation to the configuration defined, it is possible to have two different maps. Data in reading: Type Address...
  • Page 29: Mechanical Dimensions

    Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 9b: Mechanical dimensions scheme for HD67672-IP-4-A1 Figure 9a: Mechanical dimensions scheme for HD67672-IP-2-A1 Figure 9d: Mechanical dimensions scheme for HD67672-MSTP-4-A1 Figure 9c: Mechanical dimensions scheme for HD67672-MSTP-2-A1 ADFweb.com Srl – IT31010 – Mareno – Treviso INFO: www.adfweb.com...
  • Page 30: Ordering Informations

    IP: BACnet/IP MSTP: BACnet MS/TP Device Family HD67672: BACnet Slave / Modbus Slave - Converter Order Code: HD67672-IP-2-A1 BACnet/IP slave/ Modbus slave – Converter (Modbus over RS232) Order Code: HD67672-IP-4-A1 BACnet/IP slave / Modbus slave – Converter (Modbus over RS485) Order Code: HD67672-MSTP-2-A1 BACnet MS/TP slave / Modbus slave –...
  • Page 31: Other Regulations And Standards

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 31 di 32 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 32: Warranties And Technical Support

    User Manual BACnet Slave / Modbus Slave Document code: MN67672_ENG Revision 1.100 Pagina 32 di 32 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following:...

This manual is also suitable for:

Hd67672-ip-4-a1Hd67672-mstp-4-a1Hd67672-mstp-2-a1

Table of Contents