Module
5-button
Wiegand
Tamper switch
Blind
Security Relay
Module Power Supply
Except for the protection switch module, all the
from the bus. The available bus power output depends on the power supply type.
Main units 571v3 and higher can use a 3A power supply to increase the bus power
available for the modules connected.
Power supply
Specification
External supply
12 V ±15% / 2 A (3 A)
PoE
802.3af (Class 0–12.95 W)
Combined
External supply + PoE
The count of modules on the bus is limited by the available power supply output. The
maximum count of the modules on the bus is 30.
Main unit
(571v3)
At relax
Infrared illumination
LED – call
2N TELEKOMUNIKACE a.s., www.2n.cz
Externally
mounted (visible
module)
X
X
Consumption [W]
(Maximum value)
2.376
3.06
0.072
Internally
mounted (invisible
module)
X
X
®
2N
IP Verso
Available power
24 W (36 W)
12 W
30 W (42 W)
Internally mounted
on bottom base
edge
X
modules are powered
251/302