Advertisement

Quick Links

Installation Manual
Firmware:
2.15
Version:
2.15
®
2N IP Solo
IP Intercom
www.2n.cz

Advertisement

Table of Contents
loading

Summary of Contents for Axis 2N IP Solo

  • Page 1 ® 2N IP Solo IP Intercom Installation Manual Firmware: 2.15 Version: 2.15 www.2n.cz...
  • Page 2 The 2N TELEKOMUNIKACE a.s. is a Czech manufacturer and supplier of telecommunications equipment. The product family developed by 2N TELEKOMUNIKACE a.s. includes GSM gateways, private branch exchanges (PBX), and door and lift communicators. 2N TELEKOMUNIKACE a.s. has been ranked among the Czech top companies for years and represented a symbol of stability and prosperity on the telecommunications market for almost two decades.
  • Page 3 The 2N TELEKOMUNIKACE a.s. is the holder of the ISO 9001:2009 certificate. All development, production and distribution processes of the company are managed by this standard and guarantee a high quality, technical level and professional aspect of all our products.
  • Page 4: Table Of Contents

    Content: 1. Product Overview 1.1 Components and Associated Products 1.2 Terms and Symbols 2. Description and Installation 2.1 Before You Start 2.2 Mechanical Installation 2.2.1 Main Unit Mounting 2.3 Electric Installation 2.4 Connexion des modules d’extension 2.5 Completion 3. Function and Use 3.1 Configuration 3.2 Intercom Control as Viewed by External User 3.3 Intercom Control as Viewed by Internal User...
  • Page 5: Product Overview

    1. Product Overview Here is what you can find in this section: 1.1 Components and Associated Products 1.2 Terms and Symbols 2N TELEKOMUNIKACE a.s., www.2n.cz 5/78...
  • Page 6 Basic Features ® IP Solo is an elegant and reliable intercom equipped with lots of useful functions. Thanks to SIP support and compatibility with major brands of PBX manufacturers, it ® can benefit from using VoIP networks. IP Solo can be used as a door or special purpose intercom for office buildings, residential areas and other applications.
  • Page 7 Advantages of Use Elegant design Weather resistant Various modes of installation (flush, surface, plasterboard) Sensitive microphone and loud speaker Both-way audio communication – acoustic echo cancellation Integrated colour HD camera with wide-angle lense and hidden night vision Integrated switches of electric locks with wide setting options Optional integrated RFID card reader module PoE or 12 V DC power supply Configuration using web interface or dedicated PC application...
  • Page 8: Components And Associated Products

    1.1 Components and Associated Products Main Units 2N Part No. 9155301CF Main unit Axis Part No. 01300-001 Flush mount HD camera 2N Part No. 9155301F Main unit Axis Part No. 02205-001 Flush mount Cameraless version 2N Part No. 9155301CBF Main unit Axis Part No.
  • Page 9 2N Part No. 9155301BF Main unit Axis Part No. 02204-001 Flush mount Cameraless version 2N Part No. 9155301CS Main unit Axis Part No. 01301-001 Surface mount HD camera 2N Part No. 9155301S Main unit Axis part No. 02203-001 Surface mount Cameraless version 2N Part No.
  • Page 10 2N Part No. 9155301BS Main unit Axis Part No. 02202-001 Surface mount Cameraless version 2N TELEKOMUNIKACE a.s., www.2n.cz 10/78...
  • Page 11 Mounting Accessories 2N Part No. 9155017 Flush mounting box Axis Part No. 01304-001 Designed for flush or plasterboard mounting. 2N Part No. 9155068 Backplate Axis Part No. 01305-001 For uneven surface installation 2N Part No. 9155071 Wedge backplate Axis Part No. 02077-001 25 gradient mounting backplate °...
  • Page 12 2N Part No. 9155074 Glass mount Axis Part No. 02078-001 Remember to use the uneven surface mounting ® backplate Part No. 9155068 while installing IP Solo onto a glass surface. Choose the proper frame and, if necessary, mounting box type depending on your ®...
  • Page 13 2N Part. No. 91378382 ® Indoor Touch desk stand black Axis Part No. 01425-001 2N Part Numbers: ® Indoor Touch – white 91378365WH, 01417-001 WiFi version (second Part no.)
  • Page 14 2N Part No. 91378382W ® Indoor Touch desk stand white Axis Part No. 01426-001 2N TELEKOMUNIKACE a.s., www.2n.cz 14/78...
  • Page 15 VoIP Phones 2N Part No. 91378357 Grandstream GXV3240 VoIP video telephone Axis Part No. 01422-001 GXV3240 is the successor to the popular GXV3140 model, which allows comfortable video calls in the IP network. Touchscreen and keyboard control. 2N Part No.
  • Page 16 Electric Locks Part No. 932071E BEFO 11211 12 V / 230 mA DC low consumption Part No. 932081E BEFO 11221 with momentum pin 12 V / 230 mA DC low consumption A short electrical impuls is sufficient for opening the lock. The lock remains open until someone closes the door.
  • Page 17 Part No. 932061E BEFO 211211 door signalling, low consumption 12 V / 230 mA A regular lock with a built-in contact to indicate whether the door is open or closed. Part No. 932072E BEFO 31211 fail-safe 12 V / 170 mA DC The failsafe lock is closed when electricity is switched on.
  • Page 18 FAQ: Electric locks – Difference between locks in 2N IP intercoms accesories Power Supply Part Numbers: PoE injector – without cable 91378100, 01394-001 PoE injetor – with EU cable PoE injector – with US cable 91378100E For intercom power supply via an Ethernet cable where the 91378100US, 01403-001...
  • Page 19 Two-Wire Connection Part No. 9159014EU/US/UK ® 2Wire (set of 2 adapters and power source for EU/US/UK) ® 2Wire converter allows you to use the existing wiring (2 wires) from your original door bell or door intercom to connect any IP device. No ®...
  • Page 20 2N Part No. 9159010 ® Security Relay Axis Part No. 01386-001 A handy add-on that significantly enhances door entry security as it prevents tampering with the intercom and forced unlocking. To be installed between the intercom and lock, powered by the intercom.
  • Page 21 2N Part No. 9159012 Magnetic door contact Axis Part No. 01388-001 Designed for door installation to indicate the door opening status. Used when the intercom is used for door protection, to detect whether the door is open or broken.
  • Page 22 License 2N Part No. 9137905 Enhanced Audio Axis Part No. 01376-001 2N Part No. 9137906 Enhanced Video Axis Part No. 01377-001 2N Part No. 9137907 Enhanced Integration Axis Part No. 01378-001 2N Part No. 9137908 Enhanced Security Axis Part No. 01379-001 2N Part No.
  • Page 23: Terms And Symbols

    1.2 Terms and Symbols The following symbols and pictograms are used in the manual: Safety Always abide by this information to prevent persons from injury. Warning Always abide by this information to prevent damage to the device. Caution Important information for system functionality. Useful information for quick and efficient functionality.
  • Page 24: Description And Installation

    2. Description and Installation Here is what you can find in this section: 2.1 Before You Start 2.2 Mechanical Installation 2.3 Electric Installation 2.4 Connexion des modules d’extension 2.5 Completion 2N TELEKOMUNIKACE a.s., www.2n.cz 24/78...
  • Page 25: Before You Start

    2.1 Before You Start Product Completeness Check ® Before you start please check whether the contents of the package of your new 2N IP Solo complies with the following list. ® 1x 2N IP Solo Surface installation Installation manual 1x frame for suface installation frame holder set 3x dowels 3x screws...
  • Page 26: Mechanical Installation

    2.2 Mechanical Installation Mounting Types Overview Refer to the table below for a list of mounting types and necessary components. You can assemble multiple units in all mounting types. Flush mounting – classic bricks incl. hollow bricks, thermally insulated walls, etc. What you need for mounting: a properly cut hole as instructed in the box package plaster, mounting glue, mounting foam or mortar as necessary...
  • Page 27 Surface mounting concrete and steel structures, entry barrier columns, interior, etc. What you need for mounting: ® IP Solo We recommend you to use a mounting backplate, Part No. 9155068 , for uneven surfaces. Glass mounting glass surface What you need for mounting: ®...
  • Page 28 Caution The warranty does not apply to the product defects and failures arisen as a result of improper mounting (in contradiction herewith). The manufacturer is neither liable for damage caused by theft within an area that is accessible after the attached electric lock is switched. The product is not designed as a burglar protection device except when used in combination with a standard lock, which has the security function.
  • Page 29 Caution Make sure that the diameter of the dowel holes is accurate to avoid falling out of the dowels! Use the mounting glue to secure the dowels if necessary. Make sure that the depth of the dowel holes is accurate! Do not use low-quality dowels to avoid their pulling out of the wall! Having removed the front panel, make sure that no dirt gets inside the product (especially onto the sealing surface).
  • Page 30 Safety Eliminate the risk of personal injury! Surface mounting is not recommended for narrow passages or places where people's attention is distracted by something else. The manufacturer shall not be liable for injuries in such cases! Module Installation 2.2.1 Main Unit Mounting 2N TELEKOMUNIKACE a.s., www.2n.cz 30/78...
  • Page 31: Main Unit Mounting

    2.2.1 Main Unit Mounting Flush mounting – classic bricks and plasterboard 2N TELEKOMUNIKACE a.s., www.2n.cz 31/78...
  • Page 32 2N TELEKOMUNIKACE a.s., www.2n.cz 32/78...
  • Page 33 2N TELEKOMUNIKACE a.s., www.2n.cz 33/78...
  • Page 34 2N TELEKOMUNIKACE a.s., www.2n.cz 34/78...
  • Page 35 Wall (surface) mounting 2N TELEKOMUNIKACE a.s., www.2n.cz 35/78...
  • Page 36 2N TELEKOMUNIKACE a.s., www.2n.cz 36/78...
  • Page 37 2N TELEKOMUNIKACE a.s., www.2n.cz 37/78...
  • Page 38 Wall (surface) mounting using backplate 2N TELEKOMUNIKACE a.s., www.2n.cz 38/78...
  • Page 39 2N TELEKOMUNIKACE a.s., www.2n.cz 39/78...
  • Page 40 2N TELEKOMUNIKACE a.s., www.2n.cz 40/78...
  • Page 41 2N TELEKOMUNIKACE a.s., www.2n.cz 41/78...
  • Page 42: Electric Installation

    2.3 Electric Installation ® This subsection describes how to install the modules, how to connect the 2N IP Solo main unit to the power supply and LAN and how to connect other elements. Caution The device must be part of the electrical system of the building. Mounting Preparation ®...
  • Page 43 PoE Power Supply ® IP Solo is compatible with the PoE 802.3af (Class 0–12,95 W) technology and can be fed directly from the LAN via the compatible network elements. If your LAN does ® not support this technology, insert a PoE injector, Part No. 91378100, between 2N Solo and the nearest network element.
  • Page 44 Main Unit Connector Configuration Legend LAN (PoE according to 802.1af) connector (PoE) IN1 terminals for input in passive/ active mode (−30 V to +30 V DC) OFF = open OR U > 1.5 V ON = closed contact OR U <...
  • Page 45 Output wiring diagram for Relay terminals The electric lock is opened by power supply connection. The magnetic lock is opened by power supply disconnection. 2N TELEKOMUNIKACE a.s., www.2n.cz 45/78...
  • Page 46 Wiring Diagram of IN1 connector in active mode Wiring Diagram of IN1 connector in passive mode 2N TELEKOMUNIKACE a.s., www.2n.cz 46/78...
  • Page 47 Reset Button Located among the main unit connectors, the Reset button helps you reset the factory default values, restart the device, find the device IP address and switch the static /dynamic mode. IP Address Finding Follow the instructions below to identify the current IP address Press and hold the RESET button.
  • Page 48 Wait until the red LED goes off and the acoustic signal can be heard (approx. for another 3 s). Release the RESET button. The following network parameters will be set after restart: IP address: 192.168.1.100 Network mask: 255.255.255.0 Default gateway: 192.168.1.1 Dynamic IP Address Setting Follow the instructions below to switch on the Dynamic IP address...
  • Page 49 Factory Reset Follow the instructions below to reset the factory default values Press and hold the RESET button. Wait until the red and green LEDs go on simultaneously and the acoustic signal can be heard (approx. 15–35 s). Wait until the red LED goes off and the acoustic signal can be heard (approx.
  • Page 50 Note The time interval between the short press of RESET and reconnection ® after restart is 26 s for 2N IP Solo. Available Outputs Location Name Description Main Unit Relay 1 Passive switch: NO/NC contact, up to 30 V / 1 A AC/DC Output Active switch output: 8 up to 12 V DC depending on power supply (PoE: 10 V;...
  • Page 51 Main Unit LED Pictograms Main Unit LED Pictogram Layout 2N TELEKOMUNIKACE a.s., www.2n.cz 51/78...
  • Page 52: Connexion Des Modules D'extension

    2.4 Connexion des modules d’extension ® IP Solo permet de connecter les modules d'extension suivants : Security relay Relais de sécurité ® relais de sécurité 2N (réf. 9159010) est utilisé pour améliorer la sécurité entre ® l'interphone et la serrure électrique connectée. The IP Intercom Security Relay designed for any 2N IP intercom...
  • Page 53 Installation : ® Installez le relais de sécurité 2N sur un câble à deux fils entre l'interphone et la serrure électrique à l'intérieur de la zone à sécuriser (généralement derrière la porte). L'appareil est alimenté et contrôlé via ce câble à deux fils et peut donc être ajouté à une installation existante.
  • Page 54 Configuration : ® Connectez le relais de sécurité 2N à la sortie du commutateur défini pour l’ Interphone. Pour cela, reportez-vous au manuel de configuration des interphones IP 2N. ® Assurez-vous qu'une LED au moins sur le relais de sécurité 2N est allumée ou clignote.
  • Page 55 Connexion : 2N TELEKOMUNIKACE a.s., www.2n.cz 55/78...
  • Page 56: Completion

    2.5 Completion Installation Completion Check the connection of all wires and the RJ-45 plug to the board connector. Caution All unused connectors have to have tightened screws in order to avoid vibration caused by sound. Nametag Placing Every intercom package includes a piece of transparent foil, which can be laser printed.
  • Page 57 Version A Screw the flush mounting frame in the upper and bottom parts. Version B Hang the surface mounting frame on the hook in the upper part and then screw it tight in the bottom part. Caution Improper mounting may deteriorate the intercom waterproofness and water may damage the electronic part.
  • Page 58: Function And Use

    3. Function and Use ® This section describes the basic and extending functions of the the 2N IP Solo product. Here is what you can find in this section: 3.1 Configuration 3.2 Intercom Control as Viewed by External User 3.3 Intercom Control as Viewed by Internal User 3.4 Maintenance 3.5 Downloads 2N TELEKOMUNIKACE a.s., www.2n.cz...
  • Page 59: Configuration

    3.1 Configuration ® Configure IP Solo using your PC with any internet browser: Launch your internet browser (Internet Explorer, Firefox, etc.). Enter the IP address of your intercom ( http://192.168.1.100/ , e.g.). Log in using the username Admin and password You have to know your intercom IP address to log in to the integrated web server.
  • Page 60 IP Address Retrieval ® Take the following steps to retrieve the IP Solo IP address: ® Connect (or, if connected, disconnect and reconnect) IP Solo to the power supply. Wait for the second sound signal Press the quick dial button on the main unit 5 times. ®...
  • Page 61 Dynamic/Static IP Address Switching Take the following steps to switch the dynamic and static IP address mode in ® IP Solo ® Connect (or, if connected, disconnect and reconnect) IP Solo to the power supply. Wait for the first sound signal Press the quick dial button on the main unit 15 times.
  • Page 62: Intercom Control As Viewed By External User

    3.2 Intercom Control as Viewed by External User Quick Dial Buttons Press the quick dial button on the main unit to dial the first position in the phone directory (Phone Book). By pressing the quick dial buttons you dial the phone numbers assigned to the particular Phone Book position.
  • Page 63: Intercom Control As Viewed By Internal User

    3.3 Intercom Control as Viewed by Internal User Call Answering ® You can answer the incoming calls to the IP Solo intercom using your phone like any other calls. You can unlock the door, activate/deactivate a user/profile via your phone keypad during the call. The calls, however, are time-limited to avoid ®...
  • Page 64: Maintenance

    3.4 Maintenance Cleaning If used frequenly, the device surface, the keypad in particular, gets dirty. To clean it, use a piece of soft cloth moistened with clean water. We recommend you to follow these principles while cleaning: Never use aggressive detergents (such as abrasives or strong disinfectants). Use suitable cleaning agents for glass lens cleaning (cleaners for glasses, optic devices screens, etc.) Clean the device in dry weather in order to make waste water evaporate quickly.
  • Page 65: Downloads

    3.5 Downloads Templates Nameplates Software ® IP Eye ® Network Scanner 2N TELEKOMUNIKACE a.s., www.2n.cz 65/78...
  • Page 66: Technical Parameters

    4. Technical Parameters Signalling protocol SIP (UDP, TCP, TLS) Buttons Button design: white-backlit transparent button with replaceable nametags Button count: 1 Audio Microphone: 1 integrated microphone Amplifier: 2 W (class D) amplifier Speaker: 2 W / 8 Ω Sound pressure level (SPL max): 71 dB (for 1 kHz, distance 1 m) Output LINE OUT: 1 VRMS / 600 Ω...
  • Page 67 Camera Sensor: 1/3'' colour CMOS JPEG resolution: up to 1280 (H) x 960 (V) Video resolution: 640 (H) x 480 (V) Frame rate: up to 30 snapshots/s Sensor sensitivity: 5.6 V/lux-sec (550 nm) View angle: 128 ° (H), 95 ° (V), 134 ° (D) Infrared light: yes Sensor sensitivity without IR light: 0,1 Lux ±...
  • Page 68 Bandwidth Audio codecs PCMA, PCMU – 64 kbps (with 85.6 kbps headers) G.729 – 16 kbps (with 29.6 kbps headers) G.722 – 64 kbps (with 85.6 kbps headers) L16 / 16 kHz – 256 kbps (with 277.6 kbps headers) V i d e o c o d e c s Set the video codec data flows in the Services / Phone / Video menu for calls and in the Services / Streaming / RTSP menu for streaming.
  • Page 69 Mechanical properties Cover: robust zinc casting with surface finish (minor surface shade nuances are acceptable) 91550XX – NICKEL Material - Zamak 410 - Zn95Al4Cu1 Surface treatment - Zn/Cu20/Ni25b max. 80 µm 91550XXB – BLACK Material - Zamak 410 - Zn95Al4Cu1 Surface treatment - Cataphoretic coating Black 30 µm, RAL 9004 –...
  • Page 70: General Drawings

    4.1 General drawings Surface mounting 2N TELEKOMUNIKACE a.s., www.2n.cz 70/78...
  • Page 71 Flush mounting 2N TELEKOMUNIKACE a.s., www.2n.cz 71/78...
  • Page 72: Supplementary Information

    5. Supplementary Information Here is what you can find in this section: 5.1 Troubleshooting 5.2 Directives, Laws and Regulations 5.3 General Instructions and Cautions 2N TELEKOMUNIKACE a.s., www.2n.cz 72/78...
  • Page 73: Troubleshooting

    5.1 Troubleshooting For the most frequently asked questions refer to faq.2n.cz 2N TELEKOMUNIKACE a.s., www.2n.cz 73/78...
  • Page 74: Directives, Laws And Regulations

    5.2 Directives, Laws and Regulations ® IP Solo conforms to the following directives and regulations: 2014/35/EU for electrical equipment designed for use within certain voltage limits 2014/30/EU for electromagnetic compatibility 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2012/19/EU on waste electrical and electronic equipment Industry Canada...
  • Page 75 Caution In order to ensure the full functioning and guaranteed outputs we strongly recommend a verification of the timeliness of version of product or facility already during the installation process. The customer takes into consideration that the product or facility can achieve the guaranteed outputs and be fully operational pursuant to the producer’s instructions only by using the most recent version of product or facility, which has been tested for full interoperability and has not been determined by the producer as incompatible...
  • Page 76: General Instructions And Cautions

    5.3 General Instructions and Cautions Please read this User Manual carefully before using the product. Follow all instructions and recommendations included herein. Any use of the product that is in contradiction with the instructions provided herein may result in malfunction, damage or destruction of the product. The manufacturer shall not be liable and responsible for any damage incurred as a result of a use of the product other than that included herein, namely undue application and disobedience of the recommendations and warnings in contradiction...
  • Page 77 The consumer shall, without delay, change the access password for the product after installation. The manufacturer shall not be held liable or responsible for any damage incurred by the consumer in connection with the use of the original password. The manufacturer also assumes no responsibility for additional costs incurred by the consumer as a result of making calls using a line with an increased tariff.
  • Page 78 2N TELEKOMUNIKACE a.s. Modřanská 621, 143 01 Prague 4, Czech Republic Phone: +420 261 301 500, Fax: +420 261 301 599 E-mail: sales@2n.cz Web: www.2n.cz v2.15 2N TELEKOMUNIKACE a.s., www.2n.cz 78/78...

Table of Contents