General Technical Data

AC line supply (L1, L2, L3):
Supply voltage 200-240 V units .......................... 1 x 200/208/220/230/240 V ±10%
Supply voltage 200-240 V units .......................... 3 x 200/208/220/230/240 V ±10%
Supply voltage 380-480 V units ................... 3 x 380/400/415/440/460/480 V ±10%
Supply frequency ......................................................................................... 50/60 Hz
Max. imbalance of supply voltage .................................. ±2% of rated supply voltage
Power factor/cos ϕ .................................................................. 0.90/1.0 at rated load
Max short circuit rating .................................................................................... 5000 A
VLT output data (U, V, W):
Output voltage ................................................................... 0-100% of supply voltage
Output frequency .................................................................................... 0.1 - 400 Hz
Rated motor voltage, 200-240 V units ................................. 200/208/220/230/240 V
Rated motor voltage, 380-480 V units .......................... 380/400/415/440/460/480 V
Rated motor frequency ................................................................................ 50/60 Hz
Switching on output ..................................................................................... Protected
Ramp times ............................................................................................ 0.1-600 sec.
Torque characteristics:
Starting torque ................................................................................... 150% for 1 min.
Acceleration torque ............................................................................................ 100%
Overload torque, 200-240 V .............................................................. 150% for 1 min.
Control card, digital inputs:
Number of programmable digital inputs .................................................................... 6
Terminal nos. ...................................................................... M0, M1, M2, M3, M4, M5
5
® ® ® ® ®
VLT
MICRO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT MICRO and is the answer not in the manual?

Questions and answers

juan
January 20, 2025

hola, tengo un inversor de hercios 176F7330 de la marca danfoss y se le daño una resistencia, esta exploto y no puedo ver su valor lo que me impide cambiarla, lo que quiero preguntar es si es posible que me ayuden dando algun diagrama o información en el cual indique cual es el valor de la resistencia en homs y cuantos de cuantos wats debe ser

User image 678dad90131ca

Subscribe to Our Youtube Channel

Table of Contents

Save PDF