Omron NE1A-SCPU01 - 07-2009 Operation Manual page 47

Safety network controller
Hide thumbs Also See for NE1A-SCPU01 - 07-2009:
Table of Contents

Advertisement

System Configuration
NE1A-series Controller DeviceNet Communications Disable (Standalone) Setting
IMPORTANT Use a USB port connection to disable the DeviceNet communications (stan-
When only a few I/O points are required for safety control, the NE1A-series
Controller's DeviceNet communications can be disabled so that it can be used
as a Standalone Controller.
Use the Network Configurator to disable the DeviceNet communications
(standalone).
Emergency stop
buttons
USB communications
Network Configurator
dalone). With Controllers that support EtherNet/IP, either the USB port or Eth-
erNet/IP can be used. DeviceNet communications are stopped after
DeviceNet communications are disabled (standalone), so the setting cannot
be made from the DeviceNet port.
Door switches
Two-hand switches
NE1A
(Standalone)
Contactors
Section 1-2
13