Command Reference: Function Blocks
Muting Mode
Position Detection
Parallel Muting with 2 Sensors Muting signal 11 is detected, and then mut-
Sequential Muting (Forward
Direction)
Sequential Muting (Both Direc-
tions)
182
The following table lists the conditions for sequence errors for each muting
mode.
Normal sequence
AOPD input turning OFF is detected while
muting signal 11 is ON.
ing signal 12 is detected.
Muting signal 11 is detected, and then mut-
ing signal 12 is detected.
Input Sequence
Muting signal 11 is detected, and then mut-
ing signal 12 is detected.
Output Sequence
Muting signal 22 is detected, and then mut-
ing signal 21 is detected.
Note All muting signals must turn OFF before the normal sequence.
Error sequence that may cause an error
AOPD input turning OFF is detected while
muting signal 11 is OFF.
• Muting signal 12 is detected before muting
signal 11 is detected.
• Muting signals 11 and 12 are detected
simultaneously.
• AOPD turns OFF before the normal
sequence is detected.
• Muting signal 12 is detected before muting
signal 11 is detected.
• Muting signals 11 and 12 are detected
simultaneously.
• AOPD turns OFF before the normal
sequence is detected.
• Muting signal 21 or 22 is detected before
muting signal 11 is detected.
• Muting signal 21 or 22 is detected before
muting signal 12 is detected.
• Muting signal 12 is detected before muting
signal 11 is detected.
• Muting signals 11 and 12 are detected
simultaneously.
• AOPD turns OFF before the normal
sequence is detected.
• Muting signal 21 or 22 is detected before
muting signal 11 is detected.
• Muting signal 21 or 22 is detected before
muting signal 12 is detected.
• Muting signal 12 or 21 is detected before
muting signal 22 is detected.
• Muting signals 21 and 22 are detected
simultaneously.
• AOPD turns OFF before the normal
sequence is detected.
• Muting signal 11 or 12 is detected before
muting signal 21 is detected.
• Muting signal 11 or 12 is detected before
muting signal 22 is detected.