Omron NE1A-SCPU01 - 07-2009 Operation Manual page 215

Safety network controller
Hide thumbs Also See for NE1A-SCPU01 - 07-2009:
Table of Contents

Advertisement

Command Reference: Function Blocks
Optional Output Settings
Fault Present Output Setting
Error Handling and Error Resetting
Synchronization Error
Sequence Error
The following outputs can also be used in programming. To enable any of
these optional outputs, select the checkbox on the Output Point Tab Page of
the function block properties dialog box.
• Override Status
• Synchronization Error
• Sequence Error
• Discrepancy Error (AOPD)
• Discrepancy Error (Override)
A Fault Present output can also be used in programming.
To enable this output, select the Fault Present checkbox on Output Point Tab
Page of the function block properties dialog box.
A synchronization error can be detected in any mode other than Position
Detection Mode.
A synchronization error will occur and Synchronization Error will turn ON
when the time difference between input signals for the muting signals (i.e.,
muting sensors) exceeds the synchronization time that has been set. If the
AODP input turns OFF (i.e., if the light curtain is obstructed) while there is a
synchronization error, Output Enable will turn OFF and Fault Present will turn
ON.
The condition for a synchronization error are give for each muting mode in the
following table.
Muting Mode
Position Detection
Parallel Muting with 2 Sensors
Sequential Muting (Forward
Direction)
Sequential Muting (Both Direc-
tions)
A sequence error will occur and Sequence Error will turn ON when the detec-
tion order of muting signals (i.e., muting sensors)
Condition for synchronization error
Not detected.
The time difference between muting signal 11 and
muting signal 12 has exceeded the set value of the
synchronization time.
The time difference between muting signal 11 and
muting signal 12 has exceeded the set value of the
synchronization time.
Input Sequence
The time difference between muting signal 11 and
muting signal 12 has exceeded the set value of the
synchronization time.
Input Sequence
The time difference between muting signal 21 and
muting signal 22 has exceeded the set value of the
synchronization time.
Section 8-5