Omron CS1W-SLK11-21 - 06-2004 Manual page 30

Sysmac link units
Table of Contents

Advertisement

Data Link Procedures
4. Connect the Programming Device.
Contents
Connect the Program-
ming Console or Sup-
port Software.
5. Create I/O tables.
Contents
Create the I/O tables.
6. Set the parameters for automatic data link creation.
Contents
a. Set the data link
mode to auto-
matic.
b. Set the number of
data link words.
7. Start the data links.
Contents
Start the data links.
Note Data link Start/Stop Bit (N= unit number):
CS Series: Word 0 of DM30000 + 100 × N
8. Stop the data links.
Contents
Stop the data links.
Note (a) Data link Start/Stop Bit (N= unit number):
CS Series: Word 0 of DM30000 + 100 × N
(b) The data links will not start if there is an error in the data link ta-
bles in the startup node. Data links can be started and stopped
using the CX-Net within the CX-Programmer.
Method
Use the special con-
CS-series, CVM1, and
nection cable.
CV-series PLCs only
Method
Use the SYSMAC
CS-series, CVM1, and
Support Software or
CV-series PLCs only
Programming Con-
sole.
Method
Use the SYSMAC
Data link startup node
Support Software or
only
Programming Con-
The node that is used to
sole.
start the data link is
called the startup node.
It is necessary to decide
beforehand which node
will be the startup node.
Data link startup node
only
Method
Switch the Data link
Data link startup node
Start/Stop Bit (listed
(The Start Bit can be
below) from OFF to
turned ON in more
ON using either the
then one node to
Programming Device,
make sure the data
or the user program.
links start even when
the startup node is
down.)
Method
Switch the Data link
Any node that is active
Start/Stop Bit (listed
in the data link
below) from OFF to
ON using either the
Programming Device,
or the user program.
Section 1-5
Nodes
Page
8
Nodes
Page
---
Nodes
Page
45
Nodes
Page
55, 67
Nodes
Page
55, 67
13