5 Technical specifications

5
Technical specifications
Ensure that the door operator with technical specification below is suitable for the installation.
Manufacturer:
Address:
Type:
Mains supply:
Power consumption:
Auxiliary voltage:
Max. Inertia J:
Electro-mechanical lock-
ing device:
Door opening angle:
Opening time (0° - 80°):
Closing time (90° - 10°):
HOLD open time:
Ambient temperature:
Relative humidity:
Drive unit weight:
Class of protection:
Approvals:
10
ASSA ABLOY Entrance Systems AB
Lodjursgatan 10, SE-261 44 Landskrona, Sweden
ASSA ABLOY SW60
100-240 V AC +10/-15%, 50/60 Hz, mains fuse max 10A (building install-
ation)
Max. 90 W
24 V DC, max. 400 mA (max. 1000 mA including lock)
2
For PUSH = 34 kgm
2
For PULL = 25.3 kgm
For Sliding push = 25.3 kgm
For Concealed with spring = 25.3 kgm
For Concealed without spring = 35 kgm
Inertia = Door weight x (Door width)
Selectable: 12 V DC, max. 1200 mA or 24 V DC, max. 600 mA
PUSH arm: 80° - 110°, with reveal 0 - 130 mm
PULL arm and Sliding PUSH arm: 80° - 110°, with reveal 0 - 51 mm
Concealed installation arm: 80° - 110°
Variable between 3 - 8 s
Note! If opening time is set to below 4.5 s, it does not meet the require-
ments of LOW ENERGY.
Variable between 4.5 - 9 s
2s - 6h
-20 °C to +45 °C
Max. 95%
3.4 kg
IP20
Third party approvals from established certification organizations valid
for safety in use.
Issue 2023-01-17
2
2
2
2
/ 3
1022077-en-4.0