Certifications And Standards; Technical Data; Product Safety Warnings - Assa Abloy NORTON RIXSON 5200 Series Installation Instructions Manual

Full feature low energy operator
Hide thumbs Also See for NORTON RIXSON 5200 Series:
Table of Contents

Advertisement

Contents

Certifications and Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Product Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Certifications and Standards
y ETL Certified: Operator conforms to ANSI/UL standard 325 for automatic closing doors.
y ANSI A156.19: These products are designed to conform to this specification "for power assist and low energy power
operated doors." These products are designed to exceed all the requirements for "Low Energy Power Operated Door".
y Americans with Disabilities Act (A.D.A.): These door operators can be installed and adjusted to conform with A.D.A.
regulations.
y ANSI A117.1: These door controls permit door assemblies to conform to the requirements of this specification "for
buildings and facilities - providing accessibility and usability for physically disabled people".
Technical Data
Input power:
Power supply:
Door width:
Door weight:
Push max angle:
Pull max angle:
Hold open time:
Product Safety Warnings
WARNING: To reduce risk of injury to person, use this operator only with Pedestrian Swing doors.
FOR INDOOR USE ONLY
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Install only on a properly operating and balanced door.
A door that is operating improperly could cause severe
injury. Have qualified service personnel make repairs to
any hardware before installing the operator.
3. Remove, or make inoperative, all locks and latches that
could prevent the operator from opening the door. The
operator is capable of powering a retracting latch or
other exit devices to enhance the security of the opening.
4. Do not connect the door operator to the source power
until instructed to do so.
5. Never let children operate or play with door controls.
Keep remote control (when provided) away from
children.
2
5200 Series (PUSH Side) Power Operator
120VAC, 60Hz 3.0A
24 V DC, max. 4.5 Amp. ; .4A Available for Acc.
36 - 48" (91-122 cm)
90-200 lb. (41-91 kg)
130° with reveal of 1/8" to 3-1/4" (3 to 82.5 mm)
120°
5-30 seconds (A.D.A. 5 seconds min.)
Indefinite for Hold Open Input or End Cap 3 Posi-
tion Switch
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
NOTES:
y Permanent wiring is to be employed as
required by local codes.
y Activation devices: push plates, touchless wall
switches, etc.
y Maximum wire size is:
‒ 12AWG at terminals LINE and NEUTRAL
‒ (120VAC; 60Hz) on Power Input Terminal
‒ 14AWG at all other terminals
6. Personnel should keep away from a moving door.
7. Test operator's safety features at least once a month.
After adjusting either force or limit of travel, retest
door operator's safety features. Failure to adjust
operator properly may cause severe injury or death.
8. KEEP DOOR OPERATING PROPERLY. See Door
Manufacturers Owners Manual. An improperly
operating door could cause severe injury or death.
Have a trained door systems technician make repairs.
9. SAVE THESE INSTRUCTIONS.
80-9352-0020-020 Rev 2 06/23