Before You Begin; Technical Data - Assa Abloy NORTON RIXSON D6001DE-L Series Installation Instructions Manual

Double egress power operator
Table of Contents

Advertisement

Before You Begin

y All dimensions are given in inches.
DO NOT scale drawings.
y Thickness recommended for
reinforcements in hollow metal
doors and frames is charted.
y This template information based
upon use of 5" maximum width butt
hinges.
y Frame reveal is 2-1/4" to 4-3/4" for
push arm and 1/8" to 3" for pull arm.
y Before beginning the installation,
verify that the door frame is properly
reinforced and is well anchored in
the wall. Frame header must be
straight - without warp or bow.
y Unreinforced hollow metal frames
and aluminum frames should be
prepared and fitted with 1/4-20 blind
rivet nuts, furnished by others.
y Concealed electrical conduit and
concealed switch or sensor wires
should be pulled to the frame before
proceeding.

Technical Data

Input power:
Power
consumption:
Circuit breaker:
Power supply:
Door width:
Door weight:
Door opening angle: up to 110° with reveal of 3" (7.6 cm) max
Hold open time:
4
D6001DE-L Series Double Egress Power Operator Unit
Fasteners for Frame:
y 1/4-20 Machine screws for
y #14 x 2-3/4" (70mm) long
Mounting Hardware
Backplate:
14 x 1-1/2 Oval Head Self Drilling Screw
Backplate:
1/4-20 x 1 Flat Head Machine Screw
Backplate:
1/4-20 x 5/8 Flat Head Machine Screw
Track:
Sex Nut and Bolt (SNB)
(optional)
120VAC, 60Hz
.9 amps
3 amps
24 V DC, max. 2.2 amp.
36" - 48" (91-122 cm)
100-250 lb. (43-113 kg)
0-30 seconds (A.D.A. 5 seconds min.)
Indefinite for optional Infinite Hold Open
Copyright © 2023, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in part
Approved 2023-11-10
hollow metal and aluminum.
sheet metal screws for wood.
Hollow Metal Door Frame Reinforcing
Frame Material
12 Ga.
.105
(2.66)
14 Ga.
.075
(1.90)
16 Ga.
.060
(1.52)
18 Ga.
.048
(1.21)
Door or Frame
Wood
Metal
Hollow Metal
Aluminum or Wood
NOTES:
y Permanent wiring is to be implemented as
required by local codes.
y Activation devices: push plates, access control,
mats, touchless wall switches, etc.
y Maximum wire size is:
‒ 12AWG at terminals LINE and NEUTRAL
(120VAC; 60Hz) on Power Input Terminal
mounted on inside of end cap.
‒ 14AWG at all other terminals
y Rate of operation shall not exceed 300 cycles of
opening and closing per hour.
without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
Templating based on 1/8" gap
between door and frame.
Reinforcing
Recommended
Min. Required
12 Ga.
18 Ga.
.105
.048
(2.66)
(1.21)
10 Ga.
12 Ga.
.134
.105
(3.41)
(2.66)
10 Ga.
12 Ga.
.134
.105
(3.41)
(2.66)
8 Ga.
10 Ga.
.164
.134
(4.18)
(3.41)
Drill
3/16" (4.76mm)
Drill #7 (.201 dia. or 5.10mm)
Tap 1/4-20
9/32" (7.00mm) thru
3/8" (9.50mm) door face opposite to closer
3/8" (9.50mm) thru
80-9360-1048-020 Rev 1 01/23
Frame
Door
1/8"
(3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Norton rixson d6001de-l1Norton rixson d6001de-l2

Table of Contents